Mã lỗi HP Latex 360 — Trang 13/32
Description: Curing System: Temperature sensor 2 failure or not connected
Causes: Temperature sensor 2.
Remedy: Call agent: • Restart the printer. Service engineer: • Reseat/replace Temp. sensor 2.
Description: Curing System: Temperature sensor 3 failure or not connected
Causes: Temperature sensor 3.
Remedy: Call agent: • Restart the printer. Service engineer: • Reseat/replace Temp. sensor 3.
Description: Curing System: Temperature sensor 4 failure or not connected
Causes: Temperature sensor 4.
Remedy: Call agent: • Restart the printer. Service engineer: • Reseat/replace Temp. sensor 4.
Description: Curing system: Fan 1 fault
Causes: Curing system: Fan 1 fault.
Remedy: Call agent: • Restart the printer. Service engineer: • Replace module 1.
Description: Curing system: Fan 2 fault
Causes: Curing system: Fan 2 fault.
Remedy: Call agent: • Restart the printer. Service engineer: • Replace module 2.
Description: Curing system: Fan 3 fault
Causes: Curing system: Fan 3 fault.
Remedy: Call agent: • Restart the printer. Service engineer: • Replace module 3.
Description: Curing system: Fan 4 fault
Causes: Curing system: Fan 4 fault.
Remedy: Call agent: • Restart the printer. Service engineer: • Replace module 4.
Description: Curing system: More than 1 fan failure
Causes: Curing fans cable.
Remedy: Call agent: • Restart the printer. Service engineer: • Reseat/replace Curing fans cable.