Remedy: If the room temperature if below 5C or the product was stored in an environment below 5C, allow the product to warm up. This can take up to four hours. Replace the printbar.
Remedy: Turn the product off, then on. Verify that the service sled transmission is in the correct position. Verify that the service sled assembly is installed correctly and not racked
Remedy: Turn the product off, then on. Check the transmission springs. Verify that the cam follower is installed. Replace the dwell gear (usually will also have 610000C8 asserts to go with ...0D) Ensure that the swingarms are engaged correctly. Ensure that the printbar is installed correctly. That it is not racked
Remedy: Turn the product off, then on. Inspect the service sled for debris (screws, plastic tabs, etc.) blocking its path. If the carriage is blocking the service sled, inspect the path between the carriage and carriage garage for debris blocking the path. Use the test Carriage function in the support test menu to confirm correct operation of the sensor carriage. NOTE: The service motor assembly is not field replaceable.
Description: Service station stall on interlock engage
Remedy: Turn the product off, then on. Ensure that the service sled can move fully from cap to Web advance position. Ensure that the service sled transmission is in the correct position. If the swingarm is in the wrong position for pick/service, that cannot be repaired during DPU.
Description: Service sled restricted movement service error
Remedy: Turn the product off, then on. Ensure that the service sled can move fully from cap to Web advance position. Ensure that the service sled transmission is in the correct position. If the swingarm is in the wrong position for pick/service, that cannot be repaired during DPU.
Description: Lift restricted movement service error
Remedy: Turn the product off, then on. Ensure that the printbar lift is not obstructed. Ensure that the printbar lift guide assembly and guide rods are not obstructed. Verify that the service sled transmission is in the correct position. Check that the printbar is not racked. If it is, remove and reinstall the printbar. The printbar lift assembly may be defective. Replace the assembly. The sensor carriage encoder strip may be dirty or damaged.
Description: Carriage restricted movement service error
Remedy: Turn the product off, then on. Check that the sensor carriage flex cable (J31) is connected correctly and not damaged. Check that the sensor carriage motor is connected. Ensure that the transmission is in the correct position. Verify that there is no debris blocking carriage movement. NOTE: The carriage movement mechanisms are not field replaceable.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.