Mã lỗi KIP 7000 — Trang 2/2
Description: Fuser Thermostat Error
Causes: 1. When the Thermostat is cut off. 2. When Interlock Signal (INTLK1) changes to H
Description: LED Head Cleaning Error
Causes: The LED Head Cleaning Motor Over Current Signal (CLMTR_OC) remains H for more than 90 seconds during LED Head cleaning.
Description: Folder Error
Causes: 1. When Error is received while Folder is connected. 2. When the Door of the Folder is opened, or Folder is jammed.
Description: Key Card Error
Causes: When Key Card is not inserted while Key Card is set.
Description: High Voltage Power Source Error
Causes: When output detection signal from HVP detects abnormal condition. Refer to page 7-31 for the detail.
Description: Optional Device Delay Jam (ex. Stacker)
Causes: After the Paper reached to the Exit Sensor, when “paper existence signal” is not received from Optional Device within the specified time.
Description: Optional Device Stay Jam (ex. Stacker)
Causes: After the Paper left the Exit Sensor, when “paper notexistence signal” is not received from Optional Device within the specified time.