Mã lỗi KIP 770

Code: E-0000

Description: Fuser Temperature Rising Error
Causes: Fuser Temperature does not reach 50C within 120 seconds after turning on.

Code: E-0001

Description: Fuser Over Temperature Error
Causes: Fuser Temperature reaches over 200C.

Code: E-0002

Description: Fuser Low Temperature Errorr
Causes: 1. Fuser Temperature at the time of turning on was 50 to 100 oC, but it does not rise up to 120 oC within 150 seconds after that. 2. Fuser Temperature at the time of turning on was higher than 100 oC, but it does not rise up to the setting temperature within 270 seconds after that

Code: E-0003

Description: Fuser Temperature Abnormal Fall Error
Causes: The difference of temperature between center and side of fuser becomes 50C or more.

Code: E-0004

Description: Fuser Temperature Abnormal Fall Error
Causes: The Lamp of fuser lights (Signal HEAT1 is “H”) to heat up the Fuser Roller in the ready condition, but even 1C of temperature rise can not be accomplished within 30 seconds.

Code: E-0005

Description: Fuse Error
Causes: Fuse (F1) is broken.

Code: E-0010

Description: Main Motor Error
Causes: The Main Motor Output Detection Signal (MAINM_LD) continues to be “H” for 3 seconds or longer when the Main Motor is rotating.

Code: E-0013

Description: Paper Tray Motor Error
Causes: The Paper Tray Motor Output Detection Signal (CSETM_LD) continues to be “H” for 3 seconds or longer when the Paper Tray Motor is rotating.