Code: E-0020

Description: Counter Error
Causes: The Counter Connection Detection Signal (COUNT_OPN) continues to be “L” for 1 second or longer after turning on.

Code: E-0031

Description: Image Corona Output Error
Causes: The Image Corona Output Detection Signal (IM_LD) continues to be “L” for 1 second or longer when the Image Corona is ON.

Code: E-0032

Description: Separation Corona Output Error
Causes: The Separation Corona Output Detection Signal (AC_LD) continues to be “L” for 1 second or longer when the Separation Corona is ON.

Code: E-0033

Description: Transfer Corona Output Error.
Causes: The Transfer Corona Output Detection Signal (TR_LD) continues to be “L” for 1 second or longer when the Transfer Corona is ON.

Code: E-0034

Description: Bias Output Error
Causes: Bias Output Detection Signal (BIAS_LD) continues to be “L” for 1 second or longer when a specified bias is supplied to the corresponding Developer Unit components.

Code: E-0040

Description: Cutter Error
Causes: 1. The Cutter Home Sensor Signal (MSCUT_L or MSCUT_R) does not change to “H” within 100 millisecond since the Cutter has started the operation. 2. The Cutter Home Sensor Signal (MSCUT_L or MSCUT_R) does not change to “L” within 1 second since the Cutter has started the operation.

Code: E-0050

Description: FPGA Error
Causes: Initialization of FPGA is failed after turning on.

Code: E-0070

Description: Developer Error
Causes: 1. The Connector J-253 is not connected. 2. The Switch (MS4) is “open” condition, which detects open/close of Engine Unit or Toner Hatch.