Description: Bypass tray lift-up failure
- When a print cycle is completed, a jam is fixed, or the power switch is turned ON, if the bypass lift sensor (PS4) does not change from the unblocked to blocked condition after the lapse of a given period of time after the bypass pick-up solenoid (SD1) is turned ON, the machine retries the depressing motion. This trouble code is displayed if the PS4 is not blocked after the retry
- While the bypass lift sensor (PS4) is blocked, if the PS4 is not unblocked after the lapse of a given period of time after the bypass pick-up solenoid (SD1) is turned ON, the machine retries the lifting motion. This trouble code is displayed if the PS4 is not unblocked after the retry
Remedy: 1 Check the connector between M1-PRCB CN6 for proper connection and correct as necessary. 2 Check M1 for correct drive coupling and correct as necessary. 3 Check the connector between PS4-relay CN6-PRCB CN8 for proper connection and correct as necessary. 4 Check the connector between SD1-relay CN4-relay CN6-PRCB CN8 for proper connection and correct as necessary. 5 PS4 I/O check, sensor check. 6 M1 operation check. 7 SD1 operation check. 8 Change PRCB.
Description: Suction fan motor malfunction
- The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the connector between FM5-relay CN13-PRCB CN14 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM5 operation check. 4 Change PRCB.
Description: Abnormally low T/C ratio
- The T/C ratios detected by the TCR sensor board (TCRSB) are below the threshold for the detection of abnormally low T/C ratio for three successive times. However, if a toner empty condition is detected, this abnormality is not detected.
Remedy: 1 Check to see if developer is available. 2 Check the connector between TCRSBrelay CN14-PRCB CN10 for proper connection and correct as necessary. 3 Change TCRSB. 4 Execute “TCR AUTO ADJUST. 5 Change PRCB.
Description: Abnormally high T/C ratio
- The T/C ratios detected by the TCR sensor board (TCRSB) are above the threshold for the detection of abnormally high T/C ratio for three successive times.
- The connector between TCRSB to PRCC is disconnected
Remedy: 1 Check to see if developer is available. 2 Check the connector between TCRSBrelay CN14-PRCB CN10 for proper connection and correct as necessary. 3 Change TCRSB. 4 Execute “TCR AUTO ADJUST. 5 Change PRCB.
Description: TCR sensor adjustment failure
- When AUTO ADJUST is performed, the difference between the TCR sensor output voltage determined by TCR AUTO ADJUST and the standard voltage is greater than the given value.
Remedy: 1 Check to see if developer is available. 2 Check the connector between TCRSBrelay CN14-PRCB CN10 for proper connection and correct as necessary. 3 Change TCRSB. 4 Execute “TCR AUTO ADJUST. 5 Change PRCB.
Description: Abnormal image transfer voltage
- The image transfer voltage remains more than 100 V continuously for a given period of time while the drum remains stationary.
Remedy: 1 Check the transfer roller unit for installation. 2 Change HV1. 3 Change PRCB.
Description: Warming-up failure
- The surface temperature of the fusing roller does not reach a given level even after the lapse of a given period of time during a warm-up cycle.
Remedy: 1 Check the fusing unit for correct installation. 2 Check the open/close operation of the right door. 3 Check the fusing unit, DCPU and PRCB for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change PRCB. 6 Change DCPU.
Description: Fusing failure (abnormally high fusing temperature 1)
- The temperature detected by the thermistor/1 (TH1) remains higher than a given temperature for a given period of time.
Remedy: 1 Check the fusing unit for correct installation. 2 Check the open/close operation of the right door. 3 Check the fusing unit, DCPU and PRCB for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change PRCB. 6 Change DCPU.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.