Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub 165 — Trang 2/3

Code: C3752

Description: Fusing failure (abnormally high fusing temperature 2) • The temperature detected by the thermistor/2 (TH2) remains higher than a given temperature for a given period of time.
Causes: Fusing unit Right door switch (SW2) DC power supply (DCPU) Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation. 2 Check the open/close operation of the right door. 3 Check the fusing unit, DCPU and PRCB for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change PRCB. 6 Change DCPU.

Code: C3851

Description: temperature 2) • The temperature detected by the thermistor/2 (TH2) remains higher than a given temperature for a given period of time. C3851 Fusing failure (abnormally low fusing temperature) • The temperature detected by the thermistor/1 (TH1) remains lower than a given temperature for a given period of time.
Causes: Fusing unit Right door switch (SW2) DC power supply (DCPU) Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation. 2 Check the open/close operation of the right door. 3 Check the fusing unit, DCPU and PRCB for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change PRCB. 6 Change DCPU.

Code: C4001

Description: Faulty HSYNC • The SOS sensor does not detect a rising edge of SOS within a given period of time after the polygon motor has started turning and a laser output has been started. • The SOS sensor detects no rising edges of SOS while VIA (image area control) is ON.
Causes: PH unit C4101 Polygon motor malfunction Printer control board (PRCB)
Remedy: 1 Turn OFF and ON the power switch. 2 Check the connector between PH unit-PRCB CN1, CN2 for proper connection and correct as necessary. 3 Change PH unit. 4 Change PRCB.

Code: C4101

Description: Polygon motor malfunction • A HIGH polygon motor lock signal is not detected within a given period of time that begins 0.5 sec. after the polygon motor has started turning. • A LOW polygon motor lock signal is not detected for a continuous given period of time while the rotation of the polygon motor remains stabilized.
Causes: PH unit C4101 Polygon motor malfunction Printer control board (PRCB)
Remedy: 1 Turn OFF and ON the power switch. 2 Check the connector between PH unit-PRCB CN1, CN2 for proper connection and correct as necessary. 3 Change PH unit. 4 Change PRCB.

Code: C5102

Description: Main motor malfunction • The main motor (M1) lock signal remains HIGH for a continuous 1-sec. period at any time 1 sec. after the main motor has started turning.
Causes: Main motor (M1) Printer control board (PRCB) DC power supply (DCPU)
Remedy: 1 Check the connector between M1-PRCB CN6 for proper connection and correct as necessary. 2 Check M1 for correct drive coupling and correct as necessary. 3 M1 operation check. PRCB CN6-7 (LOCK) 9-D 4 Change PRCB. 5 Change DCPU.

Code: C6101

Description: Scanner home detection failure • When the power switch is turned ON or a scan operation is completed, detecting the home position fails.
Causes: Scanner motor (M4) CIS module (CIS) Printer control board (PRCB)
Remedy: 1 Turn OFF and ON the power switch. 2 Check the connector between M4-PRCB P101 for proper connection and correct as necessary. 3 Check M4 for correct drive coupling and correct as necessary. 4 Check the connector between CIS-PRCB P102 for proper connection and correct as necessary. 5 M4 operation check PRCB P101-1 to 4 11-F 6 Change M4. 7 Change CIS 8 Change PRCB.

Code: C9401

Description: Scanner lamp error • When the power switch is turned ON or a scan operation is completed, the light quantity is checked and the shading compensation is performed. At this time, trouble is detected.
Causes: CIS module (CIS) Printer control board (PRCB)
Remedy: 1 Turn OFF and ON the power switch. 2 Check the connector between CIS-PRCB P102 for proper connection and correct as necessary. 3 Change CIS 4 Change PRCB.

Code: CC102

Description: Controller - engine connection failure • The engine control system can not communicate with the controller.
Causes: Printer control board (PRCB)
Remedy: 1 Turn OFF and ON the power switch. 2 Change PRCB.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie