Mã lỗi Konica-Minolta bizhub 282

Code: C0001

Description: LCT Communication Failure
- Due to a software malfunction, etc., the time on the watchdog timer has run out and a reset is performed.
Remedy:

Code: C0202

Description: Tray 1 Elevator Failure
- The Lift-Up Sensor is not unblocked even after the set period of time has elapsed after the paper lift up operation for the drawer has begun.
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of each motor for proper drive coupling, and correct as necessary. 3 Check the PU1 connector for proper connection and correct as necessary. 4 PC6 I/O check. 5 PC12 I/O check. 6 PC114-PF I/O check. 7 PC123-PF I/O check. 8 M7 operation check. 9 M8 operation check. 10 M124-PF operation check. 11 M125-PF operation check. 12 Change PWB-A. 13 Change PWB-C2. 14 Change PU1.

Code: C0204

Description: Tray 2 Elevator Failure
- The Lift-Up Sensor is not unblocked even after the set period of time has elapsed after the paper lift up operation for the drawer has begun.
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of each motor for proper drive coupling, and correct as necessary. 3 Check the PU1 connector for proper connection and correct as necessary. 4 PC6 I/O check. 5 PC12 I/O check. 6 PC114-PF I/O check. 7 PC123-PF I/O check. 8 M7 operation check. 9 M8 operation check. 10 M124-PF operation check. 11 M125-PF operation check. 12 Change PWB-A. 13 Change PWB-C2. 14 Change PU1.

Code: C0206

Description: Tray 3 Elevator Failure
- The Lift-Up Sensor is not unblocked even after the set period of time has elapsed after the paper lift up operation for the drawer has begun.
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of each motor for proper drive coupling, and correct as necessary. 3 Check the PU1 connector for proper connection and correct as necessary. 4 PC6 I/O check. 5 PC12 I/O check. 6 PC114-PF I/O check. 7 PC123-PF I/O check. 8 M7 operation check. 9 M8 operation check. 10 M124-PF operation check. 11 M125-PF operation check. 12 Change PWB-A. 13 Change PWB-C2. 14 Change PU1.

Code: C0208

Description: Tray 4 Elevator Failure
- The Lift-Up Sensor is not unblocked even after the set period of time has elapsed after the paper lift up operation for the drawer has begun.
Remedy: 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of each motor for proper drive coupling, and correct as necessary. 3 Check the PU1 connector for proper connection and correct as necessary. 4 PC6 I/O check. 5 PC12 I/O check. 6 PC114-PF I/O check. 7 PC123-PF I/O check. 8 M7 operation check. 9 M8 operation check. 10 M124-PF operation check. 11 M125-PF operation check. 12 Change PWB-A. 13 Change PWB-C2. 14 Change PU1.

Code: C0209

Description: LCT Elevator Motor Failure
- The Elevator Motor Pulse Sensor (PC10-LCT) cannot detect both edges of H/L even after the set period of time has elapsed while the Elevator Motor (M5-LCT) is turning backward/forward (raise/lower).
Remedy:

Code: C0211

Description: Bypass Lifting Motion Failure
- The Bypass Lift Sensor (PC29) is not blocked or unblocked even after the set period of time has elapsed after the Bypass Pick-Up Solenoid (SL3) is energized after the manual feed paper take-up operation has begun.
Remedy: 1 Check the SL3 connector for proper connection and correct as necessary. 2 Check cam position.. 3 PC29 I/O check PWB-A. 4 SL3 operation check. 5 Change PWB-A.

Code: C0212

Description: LCT Ejection Failure
- See PC-407 sevice manual