Các lỗi thường gặp

Code :
  • Code: C-3901
  • Description: Inferior contact of the thermistor /1 (TH1)
    - While in the warm-up condition, when the thermistor /2 (TH2) detection temperature gets to the Ready temperature before the TH1 detection temperature, the TH1 detection temperature does not get to the Ready temperature a specified period of time after the TH2 detection temperature got to the Ready temperature.
  • Causes: Thermistor /1 (TH1) Printer control board (PRCB)
  • Code: C-3902
  • Description: Inferior contact of the thermistor /2 (TH2)
    - While in the warm-up condition, when the thermistor /1 (TH1) detection temperature gets to the Ready temperature before the TH2 detection temperature, the TH2 detection temperature does not get to the Ready temperature a specified period of time after the TH1 detection temperature got to the Ready temperature
  • Causes: Thermistor /2 (TH2) Printer control board (PRCB)
  • Code: C-3903
  • Description: Thermistor /1 (TH1) open abnormality (sub CPU detection)
    - In the sub CPU, the TH1 detection temperature detects a temperature between -8 and 20 °C for more than a specified period of time.
  • Causes: Thermistor /1 (TH1) Printer control board (PRCB)
  • Code: C-3904
  • Description: Thermistor /2 (TH2) open abnormality (sub CPU detection)
    - In the sub CPU, the TH2 detection temperature detects a temperature between -8 and 20 °C for more than a specified period of time.
  • Causes: Thermistor /2 (TH2) Printer control board (PRCB)
  • Code: C-4001
  • Description: Index board (INDEXB) contact abnormality.
  • Causes: Index board (INDEXB) Overall control board (OACB)
  • Code: C-4101
  • Description: Polygon motor (M5) speed abnormality.
    - When M5 is ON, an error signal is detected 3 times in succession within a specified period of time.
  • Causes: Polygon motor (M5) Printer control board (PRCB)
  • Code: C-4401
  • Description: Laser drive board (LDB) abnormality.
    - When an overcurrent flows for laser output.
  • Causes: Laser drive board (LDB) Overall control board (OACB)
  • Code: C-4701
  • Description: Laser index abnormality.
    - When the cycle of the index is different from an expected value.
  • Causes: Index board (INDEXB) Overall control board (OACB)