Description: • CDF50: ASIC image version failure • CDF70: ASIC image access failure • CDFA0: ASIC image error. Communication error is detected between the MFP board (MFPB) and the CCD board (CCDB).
Remedy: 1. Check the connector between MFPB CN7-CCDB PJ1 for proper connection and correct as necessary. 2. Rewrite the firmware. 3. Replace the CCD unit. 4. Replace MFPB.
Remedy: 1. Check the connectors on MFPB for proper connection and correct as necessary. 2. Replace MFPB.
Code: CE002
Description: Message and method parameter failure. MFP board (MFPB) is faulty.
Causes: • MFP board (MFPB) • Hard disk (HDD)
Remedy: 1. Turn OFF the main power switch and turn it ON again, and conduct the following setting. [Service Mode] -> [System 1] -> [Initialization] -> [Clear All Data]. 2. Format the hard disk. 3. Replace the hard disk. 4. Replace MFPB.
Code: CE101
Description: Browser finish detected. • The browser is automatically recovered (restarted) after the main body detected that the browser (separate process) has stopped with fault. • When the “Malfunction finish is detected over predetermined number of times” or “the browser task process is except in idle (printing, etc)”.
Causes: MFP board (MFPB)
Remedy: 1. Check the connectors on MFPB for proper connection and correct as necessary. 2. Replace MFPB.
Code: CE201
Description: Transmission operation log storage fault. When the transmission log storage failed, it repeats retrial until transmission operation log is stored. The trouble is detected when the retrial failed for predetermined number of times.
Causes: MFP board (MFPB)
Remedy: 1. Check the connectors on MFPB for proper connection and correct as necessary. 2. Replace MFPB.
Code: CE301 ... CE305
Description: • CE301: Referring incorrect memory • CE302: Incorrect command • CE303: Finished due to error inside Qt library • CE304: Finished due to error outside Qt library • CE305: Program forced to stop. Error occurred with the process inside the MFP controller.
Causes: MFP board (MFPB)
Remedy: 1. Check the connectors on MFPB for proper connection and correct as necessary. 2. Replace MFPB. 3. Acquire the debug logs in [Service Mode] -> [Debug Settings] and analyze them.
Code: CED01
Description: The authentication application information does not exist in the hard disk/eMMC board in the enhanced server authentication state. With “Enhanced Server Authentication” set, no authentication application registration information is found in the hard disk (HDD) or the eMMC board (eMMC).
Causes: • eMMC board (eMMC) • Hard disk (HDD)
Remedy: 1. Turn OFF and ON the main power switch. 2. Check the connector from MFPB CN1-SATAB PJ1 for proper connection and correct as necessary. 3. Check the connector between SATAB PJ2-hard disk for proper connection and correct as necessary. 4. Check eMMC for proper connection and correct as necessary. 5. Logically format the hard disk. 6. Replace the hard disk. 7. If the above actions do not solve the problem, contact KM.