Các lỗi thường gặp

Code :
  • Code: C1190
  • Description: Alignment plate motor drive malfunction
    <When FS-527 is installed> • The alignment plate home sensor (PS17) is turned neither ON nor OFF even after the set period of time has elapsed after the alignment plate motor (M13) is turned ON.
  • Remedy: 1 Check the connector between M13-FSCB PJ8 for proper connection and correct as necessary. 2 Check the connector between PS17-FSCB PJ17 for proper connection and correct as necessary. 3 Check the connector of M13 for proper drive coupling, and correct as necessary. 4 PS17 I/O check, sensor check. 5 M13 operation check. 6 Change M13. 7 Change FSCB.
  • Code: C1190
  • Description: Alignment plate R drive malfunction
    <When FS-529 is installed> • The alignment plate home sensor/R (PS9) is turned neither ON nor OFF even after the set period of time has elapsed after the alignment motor/R (M4) is turned ON.
  • Remedy: 1 Check the connector between M4-FSCB CN14 for proper connection and correct as necessary. 2 Check the connector between PS9-FSCB CN6 for proper connection and correct as necessary. 3 Check the connector of M4 for proper drive coupling, and correct as necessary. 4 PS9 I/O check, sensor check FSCB CN6-9 (ON) FS-529 B-1 5 M4 operation check FSCB CN14-5 to 8 FS-529 G-3 6 Change M4 7 Change FSCB
  • Code: C1191
  • Description: Alignment plate F drive malfunction
    <When FS-529 is installed> • The alignment plate home sensor/F (PS8) is turned neither ON nor OFF even after the set period of time has elapsed after the alignment motor/F (M3) is turned ON.
  • Remedy: 1 Check the connector between M3-FSCB CN14 for proper connection and correct as necessary. 2 Check the connector between PS8-FSCB CN6 for proper connection and correct as necessary. 3 Check the connector of M3 for proper drive coupling, and correct as necessary. 4 PS8 I/O check, sensor check. 5 M3 operation check. 6 Change M3. 7 Change FSCB.
  • Code: C1194
  • Description: Leading edge stopper motor drive malfunction
    <When FS-527 is installed> • The leading edge stopper home sensor (PS20) is turned neither ON nor OFF even after the set period of time has elapsed after the leading edge stopper motor (M14) is turned ON. <When FS-529 is installed> • The leading edge stopper home sensor (PS14) is not turned OFF after the set period of time has elapsed after the stapler motor (M8) is turned ON.
  • Remedy: 1 Check the connector between M14-FSCB PJ8 for proper connection and correct as necessary. 2 Check the connector between PS20-FSCB PJ17 for proper connection and correct as necessary. 3 Check the connector of M14 for proper drive coupling, and correct as necessary. 4 PS20 I/O check, sensor check. 5 M14 operation check. 6 Change M14. 7 Change FSCB.
  • Code: C11A1
  • Description: Tray 2 exit roller pressure/ retraction malfunction
    <When FS-527 is installed> • The exit roller pressure sensor (PS12) is turned neither ON nor OFF even after the set period of time has elapsed after the exit roller retraction motor (M9) is turned ON.
  • Remedy: 1 Check the connector between M9-FSCB PJ9 for proper connection and correct as necessary. 2 Check the connector between PS12-FSCB PJ16 for proper connection and correct as necessary. 3 Check the connector of M9 for proper drive coupling, and correct as necessary. 4 PS12 I/O check, sensor check. 5 M9 operation check. 6 Change M9. 7 Change FSCB.
  • Code: C11A1
  • Description: Exit roller pressure/ retraction malfunction
    <When FS-529 is installed> • The pick up roller position sensor (PS12) is turned neither ON nor OFF even after the set period of time has elapsed after the pick up roller position motor (M1) is turned ON.
  • Remedy: 1 Check the connector between M9-FSCB CN11 for proper connection and correct as necessary. 2 Check the connector between PS12-FSCB CN7 for proper connection and correct as necessary. 3 Check the connector of M1 for proper drive coupling, and correct as necessary. 4 PS12 I/O check, sensor check. 5 M1 operation check. 6 Change M1. 7 Change FSCB.
  • Code: C11A2
  • Description: Accommodation roller pressure/ retraction malfunction
    <When FS-527 is installed> • The accommodation roller pressure sensor (PS13) is turned neither ON nor OFF even after the set period of time has elapsed after the accommodation roller retraction motor (M10) is turned ON.
  • Remedy: 1 Check the connector between M10-FSCB PJ9 for proper connection and correct as necessary. 2 Check the connector between PS13-FSCB PJ16 for proper connection and correct as necessary. 3 Check the connector of M10 for proper drive coupling, and correct as necessary. 4 PS13 I/O check, sensor check. 5 M10 operation check. 6 Change M10. 7 Change FSCB.
  • Code: C11A7
  • Description: Tray 3 exit roller pressure/ retraction malfunction
    <When JS-603 is installed> • The tray 3 exit roller retraction sensor (PS35) is turned neither ON nor OFF even after the set period of time has elapsed after the tray 3 exit roller retraction motor (M17) is turned ON.
  • Remedy: 1 Check the connector between M17-FSCB PJ30 for proper connection and correct as necessary. 2 Check the connector between PS35-FSCB PJ12 for proper connection and correct as necessary. 3 Check the connector of M17 for proper drive coupling, and correct as necessary. 4 PS35 I/O check, sensor check. 5 M17 operation check. 6 Change M17. 7 Change FSCB.