Description: CIS LED lighting failure. At the CIS gain adjustment, the machine detected that the output of the CIS LED is lower than the specified value.
Description: CIS LED lighting abnormally. After a scan job is completed, the machine detected that the average output of the CIS LED is greater than the specified value.
Description: Standard controller configuration failure. The controller of the MFP board (MFPB) is faulty.
Causes: MFP board (MFPB)
Remedy: 1 Check to see if [Service Mode] -> [System 2] -> [Image Controller Setting has been set to “Controller 0.” If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more. 2 Check the connectors of the MFPB for proper connection and correct as necessary. 3 Replace MFPB
Description: Controller hardware error. A controller hardware error is detected in the network interface.
Causes: MFP board (MFPB)
Remedy: 1 Check to see if [Service Mode] -> [System 2] -> [Image Controller Setting has been set to “Controller 0.” If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more. 2 Check the connectors of the MFPB for proper connection and correct as necessary. 3 Replace MFPB
Description: Controller start failure. A controller start failure is detected in the controller interface.
Causes: MFP board (MFPB)
Remedy: 1 Check to see if [Service Mode] -> [System 2] -> [Image Controller Setting has been set to “Controller 0.” If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more. 2 Check the connectors of the MFPB for proper connection and correct as necessary. 3 Replace MFPB
Description: Vendor connection failure. It is detected that communications with the vendor are interrupted for a given period of time or more with “Installed” selected for the setting of vendor installation.
Remedy: 1 Check the connector between vendor-PRCB CN42 for proper connection and correct as necessary. 2 Check the connector between PRCB CN41-MFPB PJ03 for proper connection and correct as necessary. 3 Replace MFPB 4 Replace PRCB 5 Replace vendor
Description: ROM contents error upon startup (MSC). ROM contents error upon startup (scanner). A fault is detected in a sequence of ROM contents check of the MFPB during starting.
Causes:
Remedy: 1 Check the ROM version. 2 Rewrite the firmware. 3 Replace the appropriate board. MSC: MFP board (MFPB) IR: MFP board (MFPB)
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.