Code: 5102-140.10

Description: Main motor failure to turn
Main motor halls not detected.
Causes: • Main drive gearbox • Main motor (M1) • Controller board (CTLB)
Remedy: 1 Remove the main drive gearbox and check for any debris. 2 Remove the debris if any abnormality is found. 3 Check the gears of main drive gearbox for wear or damage. Replace the main drive gearbox if any abnormality is found. 4 Check M1 for proper operation. 1. Remove the main drive gearbox. Note: Do not disconnect the main drive gearbox cable. 2. Enter the Service Mode and conduct a Paper Passage Test: Select [Service Mode] -> [State Confirmation Test] -> [Paper Passage Test], and select any of the feed sections. 3. Check if M1 rotates when doing the feed test. 5 Replace the CTLB. 6 Replace the main drive gearbox.

Code: 5102-140.20

Description: Main motor failure to turn
Main motor took too long to stop.
Causes: • Main drive gearbox • Main motor (M1) • Controller board (CTLB)
Remedy: 1 Remove the main drive gearbox and check for any debris. 2 Remove the debris if any abnormality is found. 3 Check the gears of main drive gearbox for wear or damage. Replace the main drive gearbox if any abnormality is found. 4 Check M1 for proper operation. 1. Remove the main drive gearbox. Note: Do not disconnect the main drive gearbox cable. 2. Enter the Service Mode and conduct a Paper Passage Test: Select [Service Mode] -> [State Confirmation Test] -> [Paper Passage Test], and select any of the feed sections. 3. Check if M1 rotates when doing the feed test. 5 Replace the CTLB. 6 Replace the main drive gearbox.

Code: 5102-140.30

Description: Main motor failure to turn
Main motor unable to lock (before motor ID).
Causes: • Main drive gearbox • Main motor (M1) • Controller board (CTLB)
Remedy: 1 Remove the main drive gearbox and check for any debris. 2 Remove the debris if any abnormality is found. 3 Check the gears of main drive gearbox for wear or damage. Replace the main drive gearbox if any abnormality is found. 4 Check M1 for proper operation. 1. Remove the main drive gearbox. Note: Do not disconnect the main drive gearbox cable. 2. Enter the Service Mode and conduct a Paper Passage Test: Select [Service Mode] -> [State Confirmation Test] -> [Paper Passage Test], and select any of the feed sections. 3. Check if M1 rotates when doing the feed test. 5 Replace the CTLB. 6 Replace the main drive gearbox.

Code: 5102-140.40

Description: Main motor failure to turn
Main motor overspeed detected.
Causes: • Main drive gearbox • Main motor (M1) • Controller board (CTLB)
Remedy: 1 Remove the main drive gearbox and check for any debris. 2 Remove the debris if any abnormality is found. 3 Check the gears of main drive gearbox for wear or damage. Replace the main drive gearbox if any abnormality is found. 4 Check M1 for proper operation. 1. Remove the main drive gearbox. Note: Do not disconnect the main drive gearbox cable. 2. Enter the Service Mode and conduct a Paper Passage Test: Select [Service Mode] -> [State Confirmation Test] -> [Paper Passage Test], and select any of the feed sections. 3. Check if M1 rotates when doing the feed test. 5 Replace the CTLB. 6 Replace the main drive gearbox.

Code: 5102-140.60

Description: Main motor failure to turn
Main motor unable to lock (after motor ID).
Causes: • Main drive gearbox • Main motor (M1) • Controller board (CTLB)
Remedy: 1 Remove the main drive gearbox and check for any debris. 2 Remove the debris if any abnormality is found. 3 Check the gears of main drive gearbox for wear or damage. Replace the main drive gearbox if any abnormality is found. 4 Check M1 for proper operation. 1. Remove the main drive gearbox. Note: Do not disconnect the main drive gearbox cable. 2. Enter the Service Mode and conduct a Paper Passage Test: Select [Service Mode] -> [State Confirmation Test] -> [Paper Passage Test], and select any of the feed sections. 3. Check if M1 rotates when doing the feed test. 5 Replace the CTLB. 6 Replace the main drive gearbox.

Code: 5102-140.70

Description: Main motor failure to turn
Main motor out of lock detected.
Causes: • Main drive gearbox • Main motor (M1) • Controller board (CTLB)
Remedy: 1 Remove the main drive gearbox and check for any debris. 2 Remove the debris if any abnormality is found. 3 Check the gears of main drive gearbox for wear or damage. Replace the main drive gearbox if any abnormality is found. 4 Check M1 for proper operation. 1. Remove the main drive gearbox. Note: Do not disconnect the main drive gearbox cable. 2. Enter the Service Mode and conduct a Paper Passage Test: Select [Service Mode] -> [State Confirmation Test] -> [Paper Passage Test], and select any of the feed sections. 3. Check if M1 rotates when doing the feed test. 5 Replace the CTLB. 6 Replace the main drive gearbox.

Code: 5102-140.80

Description: Main motor failure to turn
Transport motor excessive PWM or overtemp.
Causes: • Main drive gearbox • Main motor (M1) • Controller board (CTLB)
Remedy: 1 Remove the main drive gearbox and check for any debris. 2 Remove the debris if any abnormality is found. 3 Check the gears of main drive gearbox for wear or damage. Replace the main drive gearbox if any abnormality is found. 4 Check M1 for proper operation. 1. Remove the main drive gearbox. Note: Do not disconnect the main drive gearbox cable. 2. Enter the Service Mode and conduct a Paper Passage Test: Select [Service Mode] -> [State Confirmation Test] -> [Paper Passage Test], and select any of the feed sections. 3. Check if M1 rotates when doing the feed test. 5 Replace the CTLB. 6 Replace the main drive gearbox.

Code: 5501-126.01

Description: AC signal abnormality
Line frequency outside operating range of device.
Causes: Power supply unit (PU)
Remedy: 1 Check the power cord for continuity. Replace if necessary. 2 Make sure the nominal voltage source is within specification. Low-voltage models: 100 to 127 V AC High-voltage models: 220 to 240 V AC 3 Check if the power supply cable is properly connected to the CTLB. Reseat the cables if any abnormality is found 4 Measure the resistance between terminals A and D of the power supply socket. 1. Turn off the printer. 2. Remove the power cord. 3. Measure the resistance between terminals A and D of the power supply socket. 4. Is the resistance approximately 30 ohms? 5 Replace the PU if any abnormality is found in the measured resistance.