Các lỗi thường gặp

Code :
  • Code: C-2403
  • Description: Toner bottle phase detection abnormality.
    - While in the power switch (SW2) ON, the toner bottle position sensor (PS28) does not turn ON within a specified period of time after the toner bottle motor (M10) turns ON.
  • Causes: Toner bottle motor (M10) Toner bottle position sensor (PS28) Printer control board (PRCB)
  • Code: C-2701
  • Description: Charging abnormality.
    - An error signal is detected 5 times in succession at prescribed intervals.
  • Causes: Charging corona High voltage unit (HV) Printer control board (PRCB)
  • Code: C-2702
  • Description: Transfer lightning abnormality.
    - There occurs a phenomenon 5 times in a job, in which an error signal is detected 3 times in succession at prescribed intervals.
  • Causes: Transfer/separation charger High voltage unit (HV) Printer control board (PRCB)
  • Code: C-2703
  • Description: Separation lightning abnormality.
    - There occurs a phenomenon 5 times in a job, in which an error signal is detected 5 times in succession at prescribed intervals.
  • Causes: Transfer/separation charger High voltage unit (HV) Printer control board (PRCB)
  • Code: C-2801
  • Description: TCR output abnormality.
    - When the TCR output is in excess of 3.0 V.
  • Causes: TCR sensor (TCRS) Printer control board (PRCB)
  • Code: C-2802
  • Description: TCR output abnormality.
    When the TCR sensor (TCRS) maximum output is 1.0 V or less
  • Causes: TCR sensor (TCRS) Printer control board (PRCB)
  • Code: C-2803 E3
  • Description: TCR output abnormality.
    - When the output ripple voltage of the TCR sensor (TCRS) is 0.5 V or less.
  • Causes: TCR sensor (TCRS) Printer control board (PRCB)
  • Code: C-2803 E4
  • Description: TCR output abnormality.
    - When the output ripple voltage of TCR sensor (TCRS) is 0.02 V or less.
  • Causes: TCR sensor (TCRS) Printer control board (PRCB)