Description: Main body control board communication abnormality 1
- Communication abnormality between the overall control board (OACB) and the scanner drive board (SDB).
Causes: Overall control board (OACB) Scanner drive board (SDB)
Description: Main body control board communication abnormality 2
- Communication abnormality, incoming command abnormality, platen operation sequence abnormality to the sub CPU in the overall control board (OACB).
Description: Sub CPU A/D conversion abnormality.
- There is no response 2 times in succession to the A/D conversion request of the overall control board (OACB).
Description: Exhaust fan /Fr (FM3) conversion abnormality.
- When FM3 is ON, an error signal is detected 5 times in succession within a specified period of time.
Causes: Exhaust fan /Fr (FM3) Printer control board (PRCB)
Description: Exhaust fan /Rr (FM9) conversion abnormality.
- When FM9 is ON, an error signal is detected 5 times in succession within a specified period of time.
Causes: Exhaust fan /Rr (FM9) Printer control board (PRCB)
Description: Power supply cooling fan (FM1) conversion abnormality.
- When FM1 is ON, an error signal is detected 5 times in succession within a specified period of time.
Causes: Power supply cooling fan (FM1) Printer control board (PRCB)