Description: The EM signal shows an abnormal condition when a specified period of time elapses after the developing suction fan (FM4) turns ON. This abnormal condition recurs when a specified period of time elapses after FM4 is turned OFF and then ON again.
Causes: Developing suction fan (FM4) Printer control board (PRCB)
Description: The EM signal shows an abnormal condition when a specified period of time elapses after the cleaner cooling fan (FM5) turns ON. This abnormal condition recurs when a specified period of time elapses after FM5 is turned OFF and then ON again.
Causes: Cleaner cooling fan (FM5) ADU drive board (ADUDB) Printer control board (PRCB)
Description: The EM signal shows an abnormal condition when a specified period of time elapses after the developing cooling fan (FM12) turns ON. This abnormal condition recurs when a specified period of time elapses after FM12 is turned OFF and then ON again.
Causes: Developing cooling fan (FM12) Printer control board (PRCB)