Code: C-1112

Description: The clincher motor home sensor / Rr (PS32) does not turn ON within a specified period of time after the clincher motor /Rr (M10) starts its operation.
Causes: FNS control board (FNSCB) Clincher motor /Rr (M10) Clincher motor home sensor /Rr (PS32)

Code: C-1113

Description: The saddle stitching stopper home sensor (PS23) does not turn ON within a specified period of time after the saddle stitching stopper motor (M18) starts its operation. Or, PS23 does not turn ON within a specified period of time after it turns OFF.
Causes: FNS control board (FNSCB) Relay board (RB) Saddle stitching stopper motor (M18) Saddle stitching stopper home sensor (PS23)

Code: C-1114

Description: The alignment home sensor /Lw (PS24) does not turn ON within a specified period of time after the alignment motor /Lw (M16) starts its operation.
Causes: FNS control board (FNSCB) Relay board (RB) Alignment motor /Lw (M16) Alignment home sensor /Lw (PS24)

Code: C-1115

Description: The folding knife home sensor (PS22) does not turn ON within a specified period of time after the folding knife motor (M19) starts the HP detection.
Causes: FNS control board (FNSCB) Folding knife motor (M19) Folding knife home sensor (PS22)

Code: C-1116

Description: The folding transfer motor (M20) does not reach the standard speed within a specified period of time after it starts its operation.
Causes: FNS control board (FNSCB) Folding transfer motor (M20)

Code: C-1124

Description: The tray upper limit sensor /Lw (PS209) or the tray lower limit sensor /Lw (PS210) does not turn ON within a specified period of time after the tray lift motor /Lw (M202) starts its operation.
Causes: FNS control board (FNSCB) PI drive board (PIDB) Tray lift motor /Lw (M202) Tray upper limit /Lw (PS209) Tray lower limit /Lw (PS210)

Code: C-1125

Description: The tray upper limit sensor /Up (PS204) or the tray lower limit sensor /Up (PS205) does not turn ON within a specified period of time after the tray lift motor /Up (M201) starts its operation.
Causes: FNS control board (FNSCB) PI drive board (PIDB) Tray lift motor /Up (M201) Tray upper limit sensor /Up (PS204) Tray lower limit sensor /Up (PS205)

Code: C-1126

Description: The transfer motor (M203) does not reach the standard speed within a specified period of time after it starts its operation.
Causes: FNS control board (FNSCB) Conveyance motor (M203)