Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub 652 — Trang 22/25

Code: CD010

Description: Hard disk unformat • Unformatted hard disk is connected.
Causes: MFP board (MFPB) Hard disk
Remedy: 1 Select [Service Mode] - [State Confirmation] - [Memory/HDD Adj.] - [HDD Format], and conduct the HDD format function. . . 2 Change hard disk. . . 3 Change MFPB

Code: CD011

Description: Hard disk out of specifications mounted • A hard disk that falls outside the specifications is connected.
Causes: Hard disk
Remedy: 1 Check the hard disk specifications. 2 Change the hard disk.

Code: CD020

Description: Hard disk verify error • The data abnormality is detected by the HDD verify check.
Causes: MFP board (MFPB) Hard disk
Remedy: 1 Check the hard disk connector for proper connection and correct as necessary. 2 Reinstall the hard disk. 3 Change hard disk. 4 Change MFPB.

Code: CD030

Description: Hard disk management information reading error • The machine fails to read administrative information data saved in the hard disk.
Causes:
Remedy:

Code: CD041 ... CD046

Description: HDD command execution error Address Mark Not Found. The error occurred inside the hard disk.
Causes: Hard disk
Remedy: 1 Check the hard disk specifications. 2 Format hard disk. 3 Change the hard disk.

Code: CD047 ... CD04B

Description: HDD SCSI library error. • The error occurred inside the hard disk.
Causes: Hard disk
Remedy: 1 Check the hard disk specifications. 2 Format hard disk. 3 Change the hard disk.

Code: CD201

Description: File memory mounting error • The file memory is not mounted. • The file has any abnormality.
Causes: MFP board (MFPB)
Remedy: 1 Check to see if the memory on MFPB is installed correctly. 2 Change the memory on MFPB. 3 Change MFPB.

Code: CD202

Description: Memory capacity discrepancy • File memory capacity on the printer control board (PRCB) is not enough. • File memory capacity necessary for duplex printing is not enough during duplex unit mounting.
Causes: MFP board (MFPB)
Remedy: 1 Check to see if the memory on MFPB is installed correctly. 2 Change the memory on MFPB. 3 Change MFPB.