Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub 654e — Trang 18/24

Code: CA052

Description: Controller hardware error A controller hardware error is detected in the network interface.
Causes: MFP board (MFPB)
Remedy: 1 Check to see if [Service Mode] -> [System 2] -> [Image Controller Setting] has been set to “Controller 0.” If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more. 2 Check the connectors of MFPB for proper connection and correct as necessary. 3 Replace MFPB

Code: CA053

Description: Controller start failure A controller start failure is detected in the controller interface.
Causes: MFP board (MFPB)
Remedy: 1 Check to see if [Service Mode] -> [System 2] -> [Image Controller Setting] has been set to “Controller 0.” If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more. 2 Check the connectors of MFPB for proper connection and correct as necessary. 3 Replace MFPB

Code: CC001

Description: Vendor connection failure It is detected that communications with the vendor are interrupted for a given period of time or more with "Installed" selected for the setting of vendor installation.
Causes: • Printer control board (PRCB) • MFP board (MFPB) • Coin vendor (Japan) • Coin vendor kit (North America, Europe)
Remedy: 1 Check the connector between vendor connector CN381-PRCB CN33 for proper connection and correct as necessary. 2 Check the connector between PRCB CN34-MFPB PJ03 for proper connection and correct as necessary. 3 Replace MFPB 4 Replace PRCB 5 Replace the vendor

Code: CC151 ... CC153

Description: ROM contents error upon startup (MSC), ROM contents error upon startup (scanner), ROM contents error upon startup (PRT)
Causes:
Remedy: 1 Check the ROM version. 2 Rewrite the firmware. 3 Replace the appropriate board. MSC: MFP board (MFPB) IR: MFP board (MFPB) PRT: Printer control board (PRCB)

Code: CC155

Description: Finisher ROM error Data of flash ROM of the finishing options is determined to be faulty when the power is turned ON.
Causes: FS control board (FSCB)
Remedy: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2 Rewrite the firmware. 3 Replace FSCB (FS-534/FS-535)

Code: CC156

Description: DF ROM error. Upgrade of the firmware has not been successful.
Causes: DF control board (DFCB)
Remedy: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2 Rewrite the firmware. 3 Replace DFCB

Code: CC157

Description: Finisher ROM error (RU) When a communication error is detected between the main body and the horizontal transport unit.
Causes: • RU control board (RUCB) • FS control board (FSCB)
Remedy: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2 Rewrite the firmware. 3 Replace RUCB 4 Replace FSCB

Code: CC158

Description: Finisher ROM error (ZU) Data of flash ROM of the z-folding unit is determined to be faulty when the power is turned ON.
Causes: ZU control board (ZUCB)
Remedy: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2 Rewrite the firmware. 3 Replace ZUCB
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie