Description: Heating roller failure to turn. During any state other than printing operation , the hard latch signal from one or both of the heating roller rotation latch detection 1 and the heating roller rotation latch detection 2 is turned ON.
Causes: • Heating roller rotation sensor (PS56) • Fusing motor (M30) • Printer control board (PRCB) • Fusing unit
Remedy: 1 Check the fusing unit for proper installation and correct as necessary. 2 Check the connector between M30-PRCB CN30 for proper connection and correct as necessary. 3 Check the connector of M30 for proper drive coupling and correct as necessary. 4 PS56 I/O check, sensor check 5 M30 operation check PRCB CN30-4 (REM) PRCB CN30-7 (LOCK) 4-K 6 PRCB ICP15 conduction check 7 Replace M30 8 Replace the fusing unit 9 Replace PRCB
Description: Fusing motor’s failure to turn. The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Causes: • Fusing motor (M30) • Printer control board (PRCB)
Remedy: 1 Check the connector between M30-PRCB CN30for proper connection and correct as necessary. 2 Check the loading status of the fusing unit drive, and correct the error as necessary. 3 M30 operation check PRCB CN30-4 (REM) PRCB CN30-7 (LOCK) 4-K 4 Replace M30 5 PRCB ICP9 conduction check 6 Replace PRCB
Description: Fusing motor’s turning at abnormal timing. The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: • Fusing motor (M30) • Printer control board (PRCB)
Remedy: 1 Check the connector between M30-PRCB CN30for proper connection and correct as necessary. 2 Check the loading status of the fusing unit drive, and correct the error as necessary. 3 M30 operation check PRCB CN30-4 (REM) PRCB CN30-7 (LOCK) 4-K 4 Replace M30 5 PRCB ICP9 conduction check 6 Replace PRCB
Description: Paper cooling fan/out’s failure to turn The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • Paper cooling fan/out (FM2) • Printer control board (PRCB)
Remedy: 1 Check the connector between FM2-relay CN323- PRCB CN1 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM2 operation check PRCB CN1-3 (DRIVE) PRCB CN1-5 (LOCK) 7-K 4 Replace FM2 5 Replace PRCB
Description: Switchback paper cooling fan/1’s failure to turn The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • Switchback paper cooling fan/1 (FM4) • Paper feed/transport drive board (PFTDB)
Remedy: 1 Check the connector between FM4-relay CN282Arelay CN280-relay CN279-relay CN271B-PFTDB CN10 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM4 operation check PFTDB CN10-11 (LOCK) 6-P 4 Replace FM4 5 PFTDB ICP9 conduction check 6 Replace PFTDB
Description: Fusing warm-up trouble After warm-up operation starts, the heating roller temperature sensor/4 does not detect a temperature as high as a predetermined one though a predetermined period of time has elapsed.
Causes: • Fusing unit • Heating roller temperature sensor/4 (TEMS4) • IH power supply (IHPU) • Noise filter (NF1) • Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, NF1 and PRCB for proper connection and correct or change as necessary. 4 Replace the fusing unit 5 Replace IHPU 6 Replace PRCB 7 Replace NF1
Description: Fusing abnormally high temperature detection (Edge of the heating roller) • The heating roller thermistor/3 continues to detect a temperature higher than a predetermined one for a predetermined period of time. • The hard protection signal at the edges of the heating side remains OFF for a predetermined continuous period of time.
Causes: • Fusing unit • Heating roller thermistor/3 (TH3) • IH power supply (IHPU) • Noise filter (NF1) • Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, NF1 and PRCB for proper connection and correct or change as necessary. 4 Replace the fusing unit 5 Replace IHPU 6 Replace PRCB 7 Replace NF1
Description: Fusing abnormally high temperature detection (Center of the heating roller) The heating roller temperature sensor/4 continues to detect a temperature higher than a predetermined one for a predetermined period of time.
Causes: • Fusing unit • Heating roller temperature sensor/4 (TEMS4) • IH power supply (IHPU) • Noise filter (NF1) • Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, NF1 and PRCB for proper connection and correct or change as necessary. 4 Replace the fusing unit 5 Replace IHPU 6 Replace PRCB 7 Replace NF1
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.