Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub 750 — Trang 13/20

Code: C-5009

Description: ADU drive serial input abnormality 2. The serial data is not received from the ADU drive board (ADUDB) with ID=7-10 within a specified period of time after ACK when the power switch (SW2) is ON.
Causes: ADU drive board (ADUDB)

Code: C-5013

Description: ADU drive communication abnormality. The communication data with ID=8-10 is not received within a specified period of time after the initial communication is established.
Causes: ADU drive board (ADUDB)

Code: C-5101

Description: An error of the EM signal is detected in succession for a specified period of time when a specified period of time elapses after the fusing motor (M4) turns ON.
Causes: Fusing motor (M4) Printer control board (PRCB)

Code: C-5301

Description: The EM signal of the power supply cooling fan /1 (FM16) shows an abnormal condition when a specified period of time elapses after FM16 turns ON. This abnormal condition recurs when a specified period of time elapses after FM16 is turned OFF and then ON again.
Causes: Power supply cooling fan /1 (FM16) DC power supply /1 (DCPS1)

Code: C-5302

Description: The EM signal shows an abnormal condition when a specified period of time elapses after the cooling fan /1 (FM1) turns ON. This abnormal condition recurs when a specified period of time elapses after FM1 is turned OFF and then ON again.
Causes: Cooling fan /1 (FM1) Printer control board (PRCB)

Code: C-5303

Description: The EM signal of the power supply cooling fan /2 (FM15) shows an abnormal condition when a specified period of time elapses after FM15 turns ON. This abnormal condition recurs when a specified period of time elapses after FM16 is turned OFF and then ON again.
Causes: Power supply cooling fan /2 (FM15) Printer control board (PRCB)

Code: C-5304

Description: The EM signal shows an abnormal condition when a specified period of time elapses after the IH cooling fan /1 (FM17) turns ON. This abnormal condition recurs when a specified period of time elapses after FM1 is turned OFF and then ON again.
Causes: IH cooling fan /1 (FM17) Printer control board (PRCB)

Code: C-5305

Description: The EM signal shows an abnormal condition when a specified period of time elapses after the fusing cooling fan (FM18) turns ON. This abnormal condition recurs when a specified period of time elapses after FM18 is turned OFF and then ON again.
Causes: Fusing cooling fan (FM18) ADU drive board (ADUDB)
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie