Các lỗi thường gặp

Code :
  • Code: CA052
  • Description: Controller hardware error A controller hardware error is detected in the network interface.
  • Causes: MFP board (MFPB)
  • Remedy: 1 Check to see if [Service Mode] -> [System 2] -> [Image Controller Setting] has been set to “Controller 0.” If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more. 2 Check the connectors of MFPB for proper connection and correct as necessary. 3 Replace MFPB
  • Code: CA053
  • Description: Controller start failure A controller start failure is detected in the controller interface.
  • Causes: MFP board (MFPB)
  • Remedy: 1 Check to see if [Service Mode] -> [System 2] -> [Image Controller Setting] has been set to “Controller 0.” If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more. 2 Check the connectors of MFPB for proper connection and correct as necessary. 3 Replace MFPB
  • Code: CC001
  • Description: Vendor connection failure It is detected that communications with the vendor are interrupted for a given period of time or more with "Installed" selected for the setting of vendor installation.
  • Causes: • Printer control board (PRCB) • MFP board (MFPB) • Coin vendor (Japan) • Coin vendor kit (North America, Europe)
  • Remedy: 1 Check the connector between vendor connector CN381-PRCB CN33 for proper connection and correct as necessary. 2 Check the connector between PRCB CN34-MFPB PJ03 for proper connection and correct as necessary. 3 Replace MFPB 4 Replace PRCB 5 Replace the vendor
  • Code: CC151 ... CC153
  • Description: ROM contents error upon startup (MSC), ROM contents error upon startup (scanner), ROM contents error upon startup (PRT)
  • Causes:
  • Remedy: 1 Check the ROM version. 2 Rewrite the firmware. 3 Replace the appropriate board. MSC: MFP board (MFPB) IR: MFP board (MFPB) PRT: Printer control board (PRCB)
  • Code: CC155
  • Description: Finisher ROM error Data of flash ROM of the finishing options is determined to be faulty when the power is turned ON.
  • Causes: FS control board (FSCB)
  • Remedy: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2 Rewrite the firmware. 3 Replace FSCB (FS-534/FS-535)
  • Code: CC156
  • Description: DF ROM error. Upgrade of the firmware has not been successful.
  • Causes: DF control board (DFCB)
  • Remedy: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2 Rewrite the firmware. 3 Replace DFCB
  • Code: CC157
  • Description: Finisher ROM error (RU) When a communication error is detected between the main body and the horizontal transport unit.
  • Causes: • RU control board (RUCB) • FS control board (FSCB)
  • Remedy: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2 Rewrite the firmware. 3 Replace RUCB 4 Replace FSCB
  • Code: CC158
  • Description: Finisher ROM error (ZU) Data of flash ROM of the z-folding unit is determined to be faulty when the power is turned ON.
  • Causes: ZU control board (ZUCB)
  • Remedy: 1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2 Rewrite the firmware. 3 Replace ZUCB