Mã lỗi Konica-Minolta bizhub 951 Pro — Trang 57/94

Code: C-1403

Description: Non-volatile memory abnormality.
Causes: FD control board (FDCB)
Remedy: 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring of FDCB, and repair it if any abnormality. 3. Reinstalling FD firmware 4. Replace FDCB

Code: C-1404

Description: Non-volatile memory abnormality.
Causes: SD control board (SDCB)
Remedy: 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring of SDCB, and repair it if any abnormality. 3. Reinstalling SD firmware 4. Replace SDCB

Code: C-1406

Description: Non-volatile memory abnormality in the PB control board (PBCB)
Causes: • PB control board (PBCB) • Control program
Remedy: 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring of PBCB, and repair it if any abnormality. 3. Reinstalling PB firmware 4. Replace PBCB.

Code: C-1407

Description: Non-volatile memory abnormality.
Causes: RU control board (RUCB)
Remedy: 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring of RUCB, and repair it if any abnormality. 3. Reinstall the RU firmware. 4. Replace RUCB

Code: C-1408

Description: Non-volatile memory abnormality.
Causes: RU control board (RUCB: RU-510)
Remedy: 1. Turn OFF the sub power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring of RUCB, and repair it if any abnormality. 3. Reinstall the RU firmware. 4. Replace RUCB

Code: C-1411

Description: 5V power abnormality in the SD drive board (SDDB)
Causes: SD drive board (SDDB)
Remedy: 1. Check the connector connection and the wiring of SDDB, and repair it if any abnormality. 2. Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. 3. Replace SDDB. 4. Replace SDCB.

Code: C-1412

Description: 24V activation failure
Causes: • Power source • FNS control board (FNSCB)
Remedy: 1. Confirm the connection from the main body to FS and if the power source is supplied. Modify if any abnormality. 2. Check FNSCB, and replace it if any abnormality.

Code: C-1432

Description: Communication error in FD
Causes: Software bug
Remedy: 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring of FDCB, and repair it if any abnormality. 3. Reinstalling FD firmware 4. Replace FDCB.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie