Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub C200R — Trang 5/10

Code: C255A

Description: Magenta TCR sensor adjustment failure
• TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Remedy: 1 Reinstall imaging unit. 2 Change imaging unit. 3 Change PRCB.

Code: C255B

Description: Yellow TCR sensor adjustment failure
• TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Remedy: 1 Reinstall imaging unit. 2 Change imaging unit. 3 Change PRCB.

Code: C255C

Description: Black TCR sensor adjustment failure
• TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Remedy: 1 Reinstall imaging unit /K. 2 Change imaging unit /K. 3 Change PRCB.

Code: C2650

Description: Main backup media access error
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error.
• The error was found when reading out the counter value.
• The machine detects that the service EEPROM board is not loaded in position.
Remedy: 1 Check the connector (CN36) on PRCB, the connector (CN1) on SVERB, and the harness between the boards for proper connection and correct as necessary. 2 Change PRCB 2.1. Turn OFF the main power switch and replace the current PRCB with a new one. (When using a PRCB of another machine in service, be sure to use a PRCB installed in the same model.) 2.2. Update the PRCB firmware. 3. After completing the firmware update, turn OFF and ON the main power switch and check to see that warm-up is started. Make sure that malfunction codes other than C2650 or improper IU/TC placement is not detected. 4. When the trouble cannot be solved, reinstall the removed PRCB to the original board. NOTE • When taking the above steps, check whether PRCB is defective or not without replacing the SVERB. 3 Change SVERB 3.1. Replace the current SVERB with a new one. 3.2. Turn ON the main power switch and check to see that warm-up is started. (One minute is spent to prepare the new SVERB for use. During the period, the control panel backlight stays off.) Make sure that malfunction codes other than C2650 or improper IU/TC placement 3.3. Make the specified readjustments. 4 If the above actions do not solve the problem, contact KMBT.

Code: C2651

Description: EEPROM access error (IU C)
• An error was found when reading or writing data.
• The error was found when reading out the counter value.
Remedy: 1 Clean the connection between the imaging unit and the machine if dirty 2 Reinstall imaging unit. 3 Check the harness for proper connection and correct as necessary. 4 Change imaging unit. 5 Change PRCB.

Code: C2652

Description: EEPROM access error (IU M)
• An error was found when reading or writing data.
• The error was found when reading out the counter value.
Remedy: 1 Clean the connection between the imaging unit and the machine if dirty 2 Reinstall imaging unit. 3 Check the harness for proper connection and correct as necessary. 4 Change imaging unit. 5 Change PRCB.

Code: C2653

Description: EEPROM access error (IU Y)
• An error was found when reading or writing data.
• The error was found when reading out the counter value.
Remedy: 1 Clean the connection between the imaging unit and the machine if dirty 2 Reinstall imaging unit. 3 Check the harness for proper connection and correct as necessary. 4 Change imaging unit. 5 Change PRCB.

Code: C2654

Description: EEPROM access error (IU K)
• An error was found when reading or writing data.
• The error was found when reading out the counter value.
Remedy: 1 Clean the connection between the imaging unit and the machine if dirty 2 Reinstall imaging unit. 3 Check the harness for proper connection and correct as necessary. 4 Change imaging unit. 5 Change PRCB.