Code: C2A14

Description: Drum unit/K new release failure. The status with the new unit is not cleared after the new imaging unit or new drum unit is set.
Causes: • Imaging unit/Y,M,C • Drum unit/K • MFP board (MFPB)
Remedy: 1. Clean the connection between the imaging unit or drum unit/K and the machine if dirty. 2. Reinstall the imaging unit. 3. Reinstall the drum unit/K. 4. Check the connector between the imaging unit/Y,M,C-relay CN162,CN163,CN164-relay CN15-MFPB CN18E for proper connection and correct as necessary. 5. Check the connector between the drum unit/K-relay CN14-MFPB CN15E for proper connection and correct as necessary. 6. Replace the the corresponding imaging unit. 7. Replace the drum unit/K. 8. Replace MFPB. NOTICE • Link to the layout drawings for related parts by each trouble code (S.44. C2552, C2559, C2561, C2A11) • Link to the layout drawings for related parts by each trouble code (S.46. C2554, C255A, C2562, C2A12) • Link to the layout drawings for related parts by each trouble code (S.48. C2556, C255B, C2563, C2A13) • Link to the layout drawings for related parts by each trouble code (S.51. C2A14)

Code: C3201

Description: Fusing motor failure to turn. The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Causes: • Fusing motor (M3) • MFP board (MFPB)
Remedy: 1. Check the connector between M3-MFPB CN11E for proper connection and correct as necessary. 2. Check the loading status of the fusing unit drive, and correct the error as necessary. 3. M3 operation check • Control signal: MFPB CN11E-11 (REM), MFPB CN11E-14 (FGP) • Location of electrical component: 3-C 4. Replace M3. 5. MFPB F23E conduction check 6. Replace MFPB. NOTICE • Link to the wiring diagram (N.1. bizhub C287/C227) • Link to the layout drawings for related parts by each trouble code (S.52. C3201, C3202)

Code: C3202

Description: Fusing motor turning at abnormal timing.The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: • Fusing motor (M3) • MFP board (MFPB)
Remedy: 1. Check the connector between M3-MFPB CN11E for proper connection and correct as necessary. 2. Check the loading status of the fusing unit drive, and correct the error as necessary. 3. M3 operation check • Control signal: MFPB CN11E-11 (REM), MFPB CN11E-14 (FGP) • Location of electrical component: 3-C 4. Replace M3. 5. MFPB F23E conduction check 6. Replace MFPB. NOTICE • Link to the wiring diagram (N.1. bizhub C287/C227) • Link to the layout drawings for related parts by each trouble code (S.52. C3201, C3202)

Code: C3302

Description: Paper cooling fan failure to turn. The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • Paper cooling fan (FM8) • MFP board (MFPB)
Remedy: 1. Check the connector between FM8-relay CN27-MFPB CN12E for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM8 operation check • Control signal: MFPB CN12E-1 (REM), MFPB CN12E-3 (LOCK) • Location of electrical component: 4-C 4. Replace FM8. 5. Replace MFPB. NOTICE • Link to the wiring diagram (N.1. bizhub C287/C227) • Link to the layout drawings for related parts by each trouble code (S.53. C3302)

Code: C3425

Description: Fusing warm-up trouble. • Detected temperature of the heating roller temperature sensor (TEMS) does not go up a given range of temperature even after a lapse of given period of time at warm up. • The temperature detected by the heating roller temperature sensor (TEMS) does not shift from the pre-standby state or the post-print color printing-enable wait state even after the lapse of a predetermined period of time after the completion of warm-up.
Causes: • Fusing unit • Heating roller temperature sensor (TEMS) • DC power supply (DCPU) • MFP board (MFPB)
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the connector between the fusing unit-relay CN3-DCPU CN002 for proper connection and correct as necessary. 4. Check the connector between the fusing unit-relay CN4-MFPB CN16E for proper connection and correct as necessary. 5. Replace the fusing unit. 6. Replace MFPB. 7. Replace DCPU. NOTICE • Link to the layout drawings for related parts by each trouble code (S.54. C3425)

Code: C3722

Description: Fusing abnormally high temperature detection (Edge of the heating roller). C3722: • Detected temperature of the heating roller thermistor/1 (TH1) goes beyond a given temperature for a given period of time consecutively. • The hard protector signal remains LOW for a predetermined continuous period of time.
Causes: • Fusing unit • C3722: Heating roller thermistor/1 (TH1) • C3725: Heating roller temperature sensor (TEMS) • C3726: Heating roller thermistor/2 (TH2) • DC power supply (DCPU) • MFP board (MFPB)
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the connector between the fusing unit-relay CN4-MFPB CN16E for proper connection and correct as necessary. 4. Replace the fusing unit. 5. Replace DCPU. 6. Replace MFPB. NOTICE • Link to the layout drawings for related parts by each trouble code (S.55. C3722, C3922) • Link to the layout drawings for related parts by each trouble code (S.56. C3725, C3825, C3925) • Link to the layout drawings for related parts by each trouble code (S.57. C3726, C3826, C3926)

Code: C3725

Description: Fusing abnormally high temperature detection (Main of the heating side). Detected temperature of the heating roller temperature sensor (TEMS) goes beyond a given temperature for a given period of time consecutively.
Causes: • Fusing unit • C3722: Heating roller thermistor/1 (TH1) • C3725: Heating roller temperature sensor (TEMS) • C3726: Heating roller thermistor/2 (TH2) • DC power supply (DCPU) • MFP board (MFPB)
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the connector between the fusing unit-relay CN4-MFPB CN16E for proper connection and correct as necessary. 4. Replace the fusing unit. 5. Replace DCPU. 6. Replace MFPB. NOTICE • Link to the layout drawings for related parts by each trouble code (S.55. C3722, C3922) • Link to the layout drawings for related parts by each trouble code (S.56. C3725, C3825, C3925) • Link to the layout drawings for related parts by each trouble code (S.57. C3726, C3826, C3926)

Code: C3726

Description: Fusing abnormally high temperature detection (Center of the heating side). • Detected temperature of the heating roller thermistor/2 (TH2) goes beyond a given temperature for a given period of time consecutively. • The hard protector signal remains LOW for a predetermined continuous period of time.
Causes: • Fusing unit • C3722: Heating roller thermistor/1 (TH1) • C3725: Heating roller temperature sensor (TEMS) • C3726: Heating roller thermistor/2 (TH2) • DC power supply (DCPU) • MFP board (MFPB)
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the connector between the fusing unit-relay CN4-MFPB CN16E for proper connection and correct as necessary. 4. Replace the fusing unit. 5. Replace DCPU. 6. Replace MFPB. NOTICE • Link to the layout drawings for related parts by each trouble code (S.55. C3722, C3922) • Link to the layout drawings for related parts by each trouble code (S.56. C3725, C3825, C3925) • Link to the layout drawings for related parts by each trouble code (S.57. C3726, C3826, C3926)