Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub C25

Code: 0010

Description: Color PC drum motor malfunction
• The color PC drum motor does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the color PC drum motor is being rotated.
Remedy: 1 Check the connector between M4-PRCB PJ12 for proper connection and correct as necessary. 2 Check the M4 connector for proper drive coupling and correct as necessary. 3 M4 operation check. 4 Change M4. 5 Change PRCB.

Code: 0017

Description: Main motor malfunction
• The main motor does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the main motor is being rotated.
Remedy: 1 Check the connector between M2-PRCB PJ11 for proper connection and correct as necessary. 2 Check the M2 connector for proper drive coupling and correct as necessary. 3 M2 operation check. 4 Change M2. 5 Change PRCB.

Code: 0018

Description: Developing motor malfunction
• The developing motor does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the developing motor is being rotated.
Remedy: 1 Check the connector between M1-PRCB PJ11 for proper connection and correct as necessary. 2 Check the M1 connector for proper drive coupling and correct as necessary. 3 M1 operation check. 4 Change M1. 5 Change PRCB.

Code: 004A

Description: Cooling fan motor malfunction
• The cooling fan motor does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the cooling fan motor is being rotated.
Remedy: 1 Check the connector between FM11-relay CN27-PRCB PJ10 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM11 operation check. 4 Change FM11. 5 Change PRCB.

Code: 004E

Description: DC power supply fan motor malfunction
• The DC power supply fan motor does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the DC power supply fan motor is being rotated.
Remedy: 1 Check the connector between FM10-relay CN43-PRCB PJ3 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM10 operation check. 4 Change FM10. 5 Change PRCB.

Code: 0062

Description: Tray 3 media feed motor malfunction
• The motor lock signal remains HIGH for a given period of consecutive time while the media feed motor is being rotated.
Remedy: 1 Check the connector between M1-PCCB PJ3 for proper connection and correct as necessary. 2 Check the connector between PCCB PJ1, PJ2-relay CN53-PRCB PJ7 for proper connection and correct as necessary. 3 Check the M1 connector for proper drive coupling and correct as necessary. 4 M1 operation check. 5 Change M1. 6 Change PCCB. 7 Change PRCB.

Code: 0094

Description: 2nd image transfer pressure / retraction failure
• The IDC sensor does not come into the condition where the level detection is available (retracted position = IDC sensor shutter is open) within a given period of time after the 2nd transfer release solenoid has turned ON.
• The IDC sensor does not come into the condition where the level detection is not available (pressed position = IDC sensor shutter is closed) within a given period of time after the 2nd transfer release solenoid has turned ON.
Remedy: 1 Check the connector between M2-PRCB PJ11 for proper connection and correct as necessary. 2 Check the M2 connector for proper drive coupling and correct as necessary. 3 Check the connector between IDC-PRCB PJ19 for proper connection and correct as necessary. 4 Check the connector between SD2-relay CN23-PRCB PJ24 for proper connection and correct as necessary. 5 IDC sensor check. 6 SD2 operation check. 7 M2 operation check. 8 Change SD2. 9 Change M2. 10 Change IDC. 11 Change PRCB.

Code: 0096

Description: 1st image transfer pressure / retraction failure
• The 1st transfer release sensor is not activated (retracted position) within a given period of time after the 1st transfer release solenoid has turned ON. • The 1st transfer release sensor is not deactivated (pressed position) within a given period of time after the 1st transfer release solenoid has turned ON.
Remedy: 1 Check the connector between M2-PRCB PJ11 for proper connection and correct as necessary. 2 Check the M2 connector for proper drive coupling and correct as necessary. 3 Check the connector between PS17-PRCB PJ26 for proper connection and correct as necessary. 4 Check the connector between SD1-relay CN25-PRCB PJ13 for proper connection and correct as necessary. 5 PS17 sensor check. 6 SD1 operation check. 7 M2 operation check. 8 Change PS17. 9 Change SD1. 10 Change M2. 11 Change PRCB.