Description: IU motor failure to turn. The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Causes: • IU motor (M2) • MFP board (MFPB)
Remedy: 1. Check the connector between M2-MFPB CN12E for proper connection and correct as necessary. 2. Check the connector of M2 for proper drive coupling and correct as necessary. 3. M2 operation check • Control signal: MFPB CN12E-7 (REM), MFPB CN12E-10 (FGP) • Location of electrical component: 5-C 4. Replace M2. 5. MFPB F22E conduction check 6. Replace MFPB. NOTICE • Link to the wiring diagram (N.1. bizhub C287/C227) • Link to the layout drawings for related parts by each trouble code (S.40. C2253, C2254)
Code: C2254
Description: IU motor turning at abnormal timing. The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: • IU motor (M2) • MFP board (MFPB)
Remedy: 1. Check the connector between M2-MFPB CN12E for proper connection and correct as necessary. 2. Check the connector of M2 for proper drive coupling and correct as necessary. 3. M2 operation check • Control signal: MFPB CN12E-7 (REM), MFPB CN12E-10 (FGP) • Location of electrical component: 5-C 4. Replace M2. 5. MFPB F22E conduction check 6. Replace MFPB. NOTICE • Link to the wiring diagram (N.1. bizhub C287/C227) • Link to the layout drawings for related parts by each trouble code (S.40. C2253, C2254)
Code: C2355
Description: Transfer belt cleaner cooling fan failure to turn. The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • Transfer belt cleaner cooling fan (FM2) • MFP board (MFPB)
Remedy: 1. Check the connector between FM2-relay CN139-relay CN22-MFPB CN15E for proper connection and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM2 operation check • Control signal: MFPB CN15E<B>-10 (REM), MFPB CN15E<B>-12 (LOCK) • Location of electrical component: 16-C 4. Replace FM2. 5. Replace MFPB. NOTICE • Link to the wiring diagram (N.1. bizhub C287/C227) • Link to the layout drawings for related parts by each trouble code (S.41. C2355)
Code: C2414
Description: Developing unit/K new article release. The status with the new unit is not cleared after the new developing unit is set.
Causes: • Developing unit/K • MFP board (MFPB)
Remedy: 1. Reinstall the developing unit/K. 2. Check the connector between the developing unit/K-relay CN161-relay CN15-MFPB CN18E for proper connection and correct as necessary. 3. Replace the developing unit/K. 4. Replace MFPB. NOTICE • Link to the layout drawings for related parts by each trouble code (S.42. C2414, C2558, C255C, C2564)
Code: C2551
Description: Abnormally low toner density detected cyan TCR sensor.
Remedy: 1. Perform image troubleshooting procedure if image density is low. 2. Reinstall the imaging unit. 3. Reinstall the developing unit/K. 4. Reinstall the toner cartridge. 5. Check the connector between the imaging unit or developing unit/K-relay CN161,CN162,CN163,CN164-relay CN15-MFPB CN18E for proper connection and correct as necessary. 6. M10 operation check • Control signal: MFPB CN26E-1 to 4 • Location of electrical component: 20-J 7. M7, M9 operation check • Control signal: MFPB CN28E-1 to 4 (M7), MFPB CN28E-5 to 8 (M9) • Location of electrical component: 19-J 8. If the toner empty sensor and its surroundings inside the sub hopper are dirtied with toner, clean them. 9. Replace the the corresponding imaging unit. 10. Replace the developing unit/K. 11. Replace MFPB. NOTICE • Link to the wiring diagram (N.1. bizhub C287/C227) • Link to the layout drawings for related parts by each trouble code (S.43. C2551) • Link to the layout drawings for related parts by each trouble code (S.45. C2553) • Link to the layout drawings for related parts by each trouble code (S.47. C2555) • Link to the layout drawings for related parts by each trouble code (S.49. C2557)
Code: C2552
Description: Abnormally high toner density detected cyan TCR sensor. The TC ratio of the toner determined by the toner replenishment control is detected to be the predetermined value or over for consecutive times.
Remedy: 1. Reinstall the imaging unit. 2. Reinstall the developing unit/K. 3. Check the connector between the imaging unit or developing unit/K-relay CN161,CN162,CN163,CN164-relay CN15-MFPB CN18E for proper connection and correct as necessary. 4. Replace the the corresponding imaging unit. 5. Replace the developing unit/K. 6. Replace MFPB. NOTICE • Link to the layout drawings for related parts by each trouble code (S.44. C2552, C2559, C2561, C2A11) • Link to the layout drawings for related parts by each trouble code (S.46. C2554, C255A, C2562, C2A12) • Link to the layout drawings for related parts by each trouble code (S.48. C2556, C255B, C2563, C2A13) • Link to the layout drawings for related parts by each trouble code (S.42. C2414, C2558, C255C, C2564)
Code: C2553
Description: Abnormally low toner density detected magenta TCR sensor
Remedy: 1. Perform image troubleshooting procedure if image density is low. 2. Reinstall the imaging unit. 3. Reinstall the developing unit/K. 4. Reinstall the toner cartridge. 5. Check the connector between the imaging unit or developing unit/K-relay CN161,CN162,CN163,CN164-relay CN15-MFPB CN18E for proper connection and correct as necessary. 6. M10 operation check • Control signal: MFPB CN26E-1 to 4 • Location of electrical component: 20-J 7. M7, M9 operation check • Control signal: MFPB CN28E-1 to 4 (M7), MFPB CN28E-5 to 8 (M9) • Location of electrical component: 19-J 8. If the toner empty sensor and its surroundings inside the sub hopper are dirtied with toner, clean them. 9. Replace the the corresponding imaging unit. 10. Replace the developing unit/K. 11. Replace MFPB. NOTICE • Link to the wiring diagram (N.1. bizhub C287/C227) • Link to the layout drawings for related parts by each trouble code (S.43. C2551) • Link to the layout drawings for related parts by each trouble code (S.45. C2553) • Link to the layout drawings for related parts by each trouble code (S.47. C2555) • Link to the layout drawings for related parts by each trouble code (S.49. C2557)
Code: C2554
Description: Abnormally high toner density detected magenta TCR sensor. The TC ratio of the toner determined by the toner replenishment control is detected to be the predetermined value or over for consecutive times.
Remedy: 1. Reinstall the imaging unit. 2. Reinstall the developing unit/K. 3. Check the connector between the imaging unit or developing unit/K-relay CN161,CN162,CN163,CN164-relay CN15-MFPB CN18E for proper connection and correct as necessary. 4. Replace the the corresponding imaging unit. 5. Replace the developing unit/K. 6. Replace MFPB. NOTICE • Link to the layout drawings for related parts by each trouble code (S.44. C2552, C2559, C2561, C2A11) • Link to the layout drawings for related parts by each trouble code (S.46. C2554, C255A, C2562, C2A12) • Link to the layout drawings for related parts by each trouble code (S.48. C2556, C255B, C2563, C2A13) • Link to the layout drawings for related parts by each trouble code (S.42. C2414, C2558, C255C, C2564)