  • Code: CC152
  • Description: ROM contents error upon startup (IR). A fault is detected in a sequence of ROM contents check of the MFPB during starting.
  • Causes: MFP board (MFPB)
  • Remedy: 1. Check the ROM version. 2. Rewrite the firmware. 3. Replace MFPB. NOTICE • Link to the layout drawings for related parts by each trouble code (S.60. C40A1 - C40A4, C5372, C5601 - C5606, CA051 - CA053, CC151, CC152, CC170 - CC186, CC191 - CC216, CD211 - CD242, CD401 - CD413, CD701 - CD703, CD705, CD706, CE001, CE003 - CE305, CEEE1, CEEE3)
  • Code: CC155
  • Description: Finisher ROM error (When FS-533, FS-534, FS-534SD or JS-506 is installed). Data of flash ROM of the finishing options is determined to be faulty when the main power switch is turned ON.
  • Causes: <When FS-533, FS-534 or FS-534SD is installed> • FS control board (FSCB) <When JS-506 is installed> • JS control board (JSCB)
  • Remedy: When FS-533, FS-534 or FS-534SD is installed 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace FSCB. (FS-533/FS-534/FS-534SD) When JS-506 is installed 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace JSCB. NOTICE • Link to the layout drawings for related parts by each trouble code (S.13. C1004, CC155, CD704)
  • Code: CC156
  • Description: DF ROM error (When DF-628 is installed) Upgrade of the firmware has not been successful.
  • Causes: DF control board (DFCB)
  • Remedy: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace DFCB. NOTICE • Link to the layout drawings for related parts by each trouble code (S.74. C8401, CC156)
  • Code: CC15B
  • Description: Flash ROM error (saddle) (When FS-534SD is installed) Data of flash ROM of the saddle is determined to be faulty when the main power switch is turned ON.
  • Causes: SD drive board (SDDB)
  • Remedy: 1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch. 2. Rewrite the firmware. 3. Replace SDDB. NOTICE • Link to the layout drawings for related parts by each trouble code (S.76. CC15B)
  • Code: CC163
  • Description: ROM contents error (PRT) The wrong model of firmware is detected in the engine during the initial connection to the engine is being checked.
  • Causes: • EEPROM/1 • EEPROM/2 • MFP board (MFPB
  • Remedy: 1. Rewrite the firmware. 2. Replace MFPB NOTE • When taking the above steps, check whether MFPB is defective or not without replacing the EEPROM. 1. Turn OFF the main power switch and replace the current MFPB with a new one. 2. Update the firmware. 3. After completing the firmware update, turn OFF and ON the main power switch and check to see that warm-up is started. 4. When the trouble cannot be solved, reinstall the removed MFPB to the original board. 3. If the above actions do not solve the problem, contact KM. NOTICE • Link to the layout drawings for related parts by each trouble code (S.50. C2650, CC163)
  • Code: CC164
  • Description: ROM contents error (MSC). • The wrong model of firmware is detected in the MFP board when the main power switch is turned ON. • The machine type information (Machine, Type) registered to the machine differs from the actual machine type.
  • Causes: • MFP board (MFPB) • eMMC board (eMMC)
  • Remedy: 1. Check the ROM version. 2. Check the machine type information registered and reenter as necessary. For details the machine information, see “J.2.4 Entering the machine type information”. 3. Rewrite the firmware. 4. Replace MFPB. 5. Replace eMMC. 6. If the above actions do not solve the problem, contact KM. NOTICE • Link to the layout drawings for related parts by each trouble code (S.77. CC164, CD3A0)
  • Code: CC170 ... CC174
  • Description: • CC170: Dynamic link error during starting (AP0)
    • CC171: Dynamic link error during starting (AP1)
    • CC172: Dynamic link error during starting (AP2)
    • CC173: Dynamic link error during starting (AP3)
    • CC174: Dynamic link error during starting (AP4)
    A dynamic link error occurs in the program on the MFP board due to an insufficient memory space available, a ROM fault, or other reason when the main power switch is turned ON.
  • Causes: MFP board (MFPB)
  • Remedy: 1. If the malfunction code “C-C172” has occurred, access [Service Mode] -> [System 2] -> [Image Controller Setting] and check to see if “Controller 1,” or “Others” is set for [Image Controller Setting]. If any of these is set, select “Controller 0”. 2. If the malfunction code "C-C180" has occurred, check to install the appropriate loadable device driver for an authentication unit which is installed to the MFP. When the appropriate loadable device driver is not installed, reinstall the appropriate loadable device driver. 3. Replace MFPB. 4. If the above actions do not solve the problem, contact KM. NOTICE • Link to the layout drawings for related parts by each trouble code (S.60. C40A1 - C40A4, C5372, C5601 - C5606, CA051 - CA053, CC151, CC152, CC170 - CC186, CC191 - CC216, CD211 - CD242, CD401 - CD413, CD701 - CD703, CD705, CD706, CE001, CE003 - CE305, CEEE1, CEEE3)
  • Code: CC180 ... CC186
  • Description:
    • CC180: Dynamic link error during starting (LDR) • CC181: Dynamic link error during starting (IBR) • CC182: Dynamic link error during starting (IID) • CC183: Dynamic link error during starting (IPF) • CC184: Dynamic link error during starting (IMY) • CC185: Dynamic link error during starting (SPF) • CC186: Dynamic link error during starting (OAP). A dynamic link error occurs in the program on the MFP board due to an insufficient memory space available, a ROM fault, or other reason when the main power switch is turned ON.
  • Causes: MFP board (MFPB)
  • Remedy: 1. If the malfunction code “C-C172” has occurred, access [Service Mode] -> [System 2] -> [Image Controller Setting] and check to see if “Controller 1,” or “Others” is set for [Image Controller Setting]. If any of these is set, select “Controller 0”. 2. If the malfunction code "C-C180" has occurred, check to install the appropriate loadable device driver for an authentication unit which is installed to the MFP. When the appropriate loadable device driver is not installed, reinstall the appropriate loadable device driver. 3. Replace MFPB. 4. If the above actions do not solve the problem, contact KM. NOTICE • Link to the layout drawings for related parts by each trouble code (S.60. C40A1 - C40A4, C5372, C5601 - C5606, CA051 - CA053, CC151, CC152, CC170 - CC186, CC191 - CC216, CD211 - CD242, CD401 - CD413, CD701 - CD703, CD705, CD706, CE001, CE003 - CE305, CEEE1, CEEE3)