Description: Developing motor turning at abnormal timing (K) The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: • Developing motor (M3) • MFP board (MFPB)
Remedy: 1. Check the connector between M3-MFPB CN4E for proper connection and correct as necessary. 2. Check the connector of M3 for proper drive coupling and correct as necessary. 3. M3 operation check • Control signal: MFPB CN4E-4 to 7 • Location of electrical component: 25-C 4. Replace M3. 5. MFPB F7E conduction check 6. Replace MFPB.
Description: Toner suction fan motor malfunction The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • Toner suction fan motor (FM3) • MFP board (MFPB)
Remedy: 1. Check the connectors between FM3-relay CN301-MFPB CN12E for proper connection, and correct as necessary. 2. Check the fan for possible overload and correct as necessary. 3. FM3 operation check • Control signal: MFPB CN12E-6 (LOCK) • Location of electrical component: 26-C 4. Replace FM3. (bizhub C3851/C3351 / bizhub C3851FS) 5. MFPB F2E conduction check 6. Replace MFPB.
Description: • C2411: Imaging unit/C new article release • C2412: Imaging unit/M new article release • C2413: Imaging unit/Y new article release • C2414: Imaging unit/K new article release. The status with the new unit is not cleared after the new imaging unit is set.
Causes: • Imaging unit/Y,M,C,K • MFP board (MFPB)
Remedy: 1. Reinstall imaging unit. 1. Check the connector between imaging unit-MFPB CN19E, CN20E for proper connection and correct as necessary. 1. Replace the imaging unit. 1. Replace MFPB.
Description: • C2551: Abnormally low toner density detected cyan TCR sensor • C2553: Abnormally low toner density detected magenta TCR sensor When sampling data is determined in TC ratio calculation control, TCR sensor output is lower than a predetermined value for a predetermined number of times in a row even though there is toner in the toner cartridge.
Remedy: 1. Perform image troubleshooting procedure if image density is low. 2. Reinstall the imaging unit. 3. Check the connector between imaging unit-MFPB CN19E, CN20E for proper connection and correct as necessary. 4. Check the connector between M5-MFPB CN8E for proper connection and correct as necessary. 5. Check the connector between M6-MFPB CN8E for proper connection and correct as necessary. 6. M5, M6 operation check • Control signal: MFPB CN8E-1 to 4 (M5), MFPB CN8E-5 to 8 (M6) • Location of electrical component: 23-C 7. Replace the imaging unit. 8. MFPB F5E conduction check 9. Replace MFPB.
Description: • C2552: Abnormally high toner density detected cyan TCR sensor • C2554: Abnormally high toner density detected magenta TCR sensor TC ratio in the imaging unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively.
Causes: • Imaging unit/Y,M,C,K • MFP board (MFPB)
Remedy: 1. Reinstall imaging unit. 2. Check the connector between imaging unit-MFPB CN19E, CN20E for proper connection and correct as necessary. 3. Replace the imaging unit. 4. Replace MFPB.
Description: • C2555: Abnormally low toner density detected yellow TCR sensor • C2557: Abnormally low toner density detected black TCR sensor When sampling data is determined in TC ratio calculation control, TCR sensor output is lower than a predetermined value for a predetermined number of times in a row even though there is toner in the toner cartridge.
Remedy: 1. Perform image troubleshooting procedure if image density is low. 2. Reinstall the imaging unit. 3. Check the connector between imaging unit-MFPB CN19E, CN20E for proper connection and correct as necessary. 4. Check the connector between M5-MFPB CN8E for proper connection and correct as necessary. 5. Check the connector between M6-MFPB CN8E for proper connection and correct as necessary. 6. M5, M6 operation check • Control signal: MFPB CN8E-1 to 4 (M5), MFPB CN8E-5 to 8 (M6) • Location of electrical component: 23-C 7. Replace the imaging unit. 8. MFPB F5E conduction check 9. Replace MFPB.
Description: • C2556: Abnormally high toner density detected yellow TCR sensor • C2558: Abnormally high toner density detected black TCR sensor TC ratio in the imaging unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively.
Causes: • Imaging unit/Y,M,C,K • MFP board (MFPB)
Remedy: 1. Reinstall imaging unit. 2. Check the connector between imaging unit-MFPB CN19E, CN20E for proper connection and correct as necessary. 3. Replace the imaging unit. 4. Replace MFPB.
Description: • C2559: Cyan TCR sensor adjustment failure • C255A: Magenta TCR sensor adjustment failure • C255B: Yellow TCR sensor adjustment failure • C255C: Black TCR sensor adjustment failure TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Causes: • Imaging unit/Y,M,C,K • MFP board (MFPB)
Remedy: 1. Reinstall imaging unit. 2. Check the connector between imaging unit-MFPB CN19E, CN20E for proper connection and correct as necessary. 3. Replace the imaging unit. 4. Replace MFPB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.