Description: Main motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 M1 operation check MFPB CNDM1-5 (REM) MFPB CNDM1-8 (LOCK) L-2. 5 Change MFPB. 6 Change DCPU.
Description: Main motor turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Description: Power supply cooling fan motor/ 1’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the connector of motor for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M8 operation check MFPB CNLV3-2 (ON) MFPB CNLV3-3 (LOCK) C-25. 4 Change DCPU.
Description: Cooling fan motor 2’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the connector of motor for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M22 operation check MFPB CNRE-3 (ON) MFPB CNR2FAN-6 (LOCK) L-8. 4 Change MFPB.
Description: Ozone ventilation fan motor’s failure to turn
• The fan Lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the connector of motor for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M14 operation check MFPB CNLP-9 (ON) MFPB CNLP-11 (LOCK) C-10. 4 Change MFPB.
Description: Cooling fan motor 3’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the connector of motor for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M23 operation check MFPB CNR2FAN-4 (ON) MFPB CNR2FAN-6 (LOCK) L-3. 4 Change MFPB.
Description: Cooling fan motor/1’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the connector of motor for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M12 operation check MFPB CNR2FAN-7 (ON) MFPB CNR2FAN-9 (LOCK) L-3. 4 Change MFPB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.