Các lỗi thường gặp

Code :
  • Code: C2554
  • Description: Abnormally high toner density detected magenta TCR sensor
    • TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 12 % or more for a given number of times consecutively.
  • Remedy: 1 Clean the TCR sensor window on the underside of the imaging unit if dirty 2 Reinstall imaging unit. 3 Change imaging unit. 4 Change MFPB. 5 Change PRCB.
  • Code: C2555
  • Description: Abnormally low toner density detected yellow TCR sensor
    • TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 5 % or less for a given number of times consecutively.
  • Remedy: 1 Perform image troubleshooting procedure if image density is low. 2 Clean the TCR sensor window on the underside of the imaging unit if dirty 3 M6, M7 operation check MFPB CNDM2-10 to 13 (M6) MFPB CNDM3-10 to 13 (M7) C-20 C-21. 4 Reinstall imaging unit. 5 Change imaging unit. 6 Change MFPB. 7 Change PRCB.
  • Code: C2556
  • Description: Abnormally high toner density detected yellow TCR sensor
    • TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 12 % or more for a given number of times consecutively.
  • Remedy: 1 Clean the TCR sensor window on the underside of the imaging unit if dirty 2 Reinstall imaging unit. 3 Change imaging unit. 4 Change MFPB. 5 Change PRCB
  • Code: C2557
  • Description: Abnormally low toner density detected black TCR sensor
    • TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 4 % or less for a given number of times consecutively.
  • Remedy: 1 Perform image troubleshooting procedure if image density is low. 2 Clean the TCR sensor window on the underside of the imaging unit if dirty 3 M7 operation check MFPB CNDM3-10 to 13 C-21 4 Reinstall Imaging unit. 5 Change imaging unit /K. 6 Change MFPB. 7 Change PRCB.
  • Code: C2558
  • Description: Abnormally high toner density detected black TCR sensor
    • TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 12 % or more for a given number of times consecutively.
  • Remedy: 1 Correct the TCR connection on the underside of the imaging unit if faulty. 2 Reinstall imaging unit. 3 Change imaging unit. 4 Change MFPB. 5 Change PRCB.
  • Code: C2559
  • Description: Cyan TCR sensor adjustment failure
    • TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
  • Remedy: 1 Clean the TCR sensor window on the underside of the imaging unit if dirty 2 M6, M7 operation check MFPB CNDM2-10 to 13 (M6) MFPB CNDM3-10 to 13 (M7) C-20 C-21. 3 Reinstall imaging unit. 4 Change imaging unit. 5 Change MFPB. 6 Change PRCB.
  • Code: C255A
  • Description: Magenta TCR sensor adjustment failure
  • Remedy: 1 Clean the TCR sensor window on the underside of the imaging unit if dirty 2 M6, M7 operation check MFPB CNDM2-10 to 13 (M6) MFPB CNDM3-10 to 13 (M7) C-20 C-21. 3 Reinstall imaging unit. 4 Change imaging unit. 5 Change MFPB. 6 Change PRCB.
  • Code: C255B
  • Description: Yellow TCR sensor adjustment failure
  • Remedy: 1 Clean the TCR sensor window on the underside of the imaging unit if dirty 2 M6, M7 operation check MFPB CNDM2-10 to 13 (M6) MFPB CNDM3-10 to 13 (M7) C-20 C-21. 3 Reinstall imaging unit. 4 Change imaging unit. 5 Change MFPB. 6 Change PRCB.
‹ First  < 3 4 5 6 7 8 9 >  Last ›
popup

Số lượng:

Tổng tiền:

Danh mục