Description: Scanner sequence trouble 1
• The original transport interval becomes shorter than the designed value due to an original transport control error in original reading in ADF.
Remedy: 1 Correct the harness connection between main body and ADF if faulty. 2 Change DFCB. 3 Change MFPB.
Description: Exposure turning on the lamp trouble detection
• The output from the CCD sensor is a predetermined value or less during CCD sensor gain adjustment.
Remedy: 1 Check the connection between the lamp harness and the inverter board, and correct if necessary. 2 Check the connection between REYB/ SCAN and the inverter board, and correct if necessary. 3 Check the connection between REYB/ SCAN and IPB, and correct if necessary. 4 Check that the connection between CCDB and IPB, and correct if necessary. 5 Change INVB. 6 Change scanner assy. 7 Change IPB. 8 Change CCDB. 9 Change REYB/SCAN.
Description: Exposure turning on the lamp abnormally detection
• The average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more at the end of a scan job.
Remedy: 1 Check the connection between the lamp harness and the inverter board, and correct if necessary. 2 Check the connection between REYB/ SCAN and the inverter board, and correct if necessary. 3 Check the connection between REYB/ SCAN and IPB, and correct if necessary. 4 Check that the connection between CCDB and IPB, and correct if necessary. 5 Change INVB. 6 Change scanner assy. 7 Change IPB. 8 Change CCDB. 9 Change REYB/SCAN.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.