Description: Developing unit (M) new article release
• The status with the new unit is not cleared after the new developing unit is set.
Remedy: 1 Reinstall developing unit. 2 Check the connector between developing unit-FREYB CN4, CN6, CN8, CN10 for proper connection and correct as necessary. 3 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 4 Change toner developing unit. 6 Change FREYB. 6 PRCB ICP12 conduction check. 7 Change PRCB
Description: Developing unit (Y) new article release
• The status with the new unit is not cleared after the new developing unit is set.
Remedy: 1 Reinstall developing unit. 2 Check the connector between developing unit-FREYB CN4, CN6, CN8, CN10 for proper connection and correct as necessary. 3 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 4 Change toner developing unit. 6 Change FREYB. 6 PRCB ICP12 conduction check. 7 Change PRCB
Description: Developing unit (K) new article release
• The status with the new unit is not cleared after the new developing unit is set.
Remedy: 1 Reinstall developing unit. 2 Check the connector between developing unit-FREYB CN4, CN6, CN8, CN10 for proper connection and correct as necessary. 3 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 4 Change toner developing unit. 6 Change FREYB. 6 PRCB ICP12 conduction check. 7 Change PRCB.
Description: Abnormally low toner density detected cyan TCR sensor
• When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper.
Remedy: 1 Perform image troubleshooting procedure if image density is low. 2 Reinstall developing unit. 3 Reinstall toner cartridge. 4 Check the connector between developing unit-FREYB CN4, CN6, CN8, CN10 for proper connection and correct as necessary. 5 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 6 M6, M7 operation check PRCB CN13-12 to 15 (M6) PRCB CN13-16 to 19 (M7) J-21 7 M8, M9 operation check PRCB CN12-9 to 12 (M8) PRCB CN12-13 to 16 (M9) J-10 8 If the toner empty sensor and its surroundings inside the sub hopper are dirtied with toner, clean them. 9 Change developing unit. 10 Change FREYB. 11 PRCB ICP3,4 conduction check. 12 Change PRCB.
Description: Abnormally high toner density detected cyan TCR sensor
• TC ratio in the developing unit which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively.
Remedy: 1 Reinstall developing unit. 2 Reinstall toner cartridge. 3 Check the connector between developing unit-FREYB CN4, CN6, CN8, CN10 for proper connection and correct as necessary. 4 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 5 Change developing unit. 6 Change FREYB. 7 PRCB ICP12 conduction check. 8 Change PRCB.
Description: Abnormally low toner density detected magenta TCR sensor
• When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper.
Remedy: 1 Perform image troubleshooting procedure if image density is low. 2 Reinstall developing unit. 3 Reinstall toner cartridge. 4 Check the connector between developing unit-FREYB CN4, CN6, CN8, CN10 for proper connection and correct as necessary. 5 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 6 M6, M7 operation check PRCB CN13-12 to 15 (M6) PRCB CN13-16 to 19 (M7) J-21 7 M8, M9 operation check PRCB CN12-9 to 12 (M8) PRCB CN12-13 to 16 (M9) J-10 8 If the toner empty sensor and its surroundings inside the sub hopper are dirtied with toner, clean them. 9 Change developing unit. 10 Change FREYB. 11 PRCB ICP3,4 conduction check. 12 Change PRCB.
Description: Abnormally high toner density detected magenta TCR sensor
• TC ratio in the developing unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively.
Remedy: 1 Reinstall developing unit. 2 Reinstall toner cartridge. 3 Check the connector between developing unit-FREYB CN4, CN6, CN8, CN10 for proper connection and correct as necessary. 4 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 5 Change developing unit. 6 Change FREYB. 7 PRCB ICP12 conduction check. 8 Change PRCB.
Description: Abnormally low toner density detected yellow TCR sensor
• When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper.
Remedy: 1 Perform image troubleshooting procedure if image density is low. 2 Reinstall developing unit. 3 Reinstall toner cartridge. 4 Check the connector between developing unit-FREYB CN4, CN6, CN8, CN10 for proper connection and correct as necessary. 5 Check the connector between FREYB CN1, CN2-PRCB CN4, CN5 for proper connection and correct as necessary. 6 M6, M7 operation check PRCB CN13-12 to 15 (M6) PRCB CN13-16 to 19 (M7) J-21 7 M8, M9 operation check PRCB CN12-9 to 12 (M8) PRCB CN12-13 to 16 (M9) J-10 8 If the toner empty sensor and its surroundings inside the sub hopper are dirtied with toner, clean them. 9 Change developing unit. 10 Change FREYB. 11 PRCB ICP3,4 conduction check. 12 Change PRCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.