Code: C5103

Description: Transport motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the connector between M1-PRCB CN14 for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 M1 operation check PRCB CN14-2 (REM) PRCB CN14-5 (LOCK) C-2 to 5. 4 Change M1. 5 Change PRCB.

Code: C5351

Description: Power supply cooling fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the connector between FM1-PRCB CN13 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM1 operation check PRCB CN13-3 (LOCK) J-20 4 Change FM1. 5 PRCB ICP3 conduction check. 6 Change PRCB.

Code: C5354

Description: Exhaust fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the connector between FM3-relay CN88-PRCB CN15 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM3 operation check PRCB CN15-8 (LOCK). 4 Change FM3. 5 Change PRCB.

Code: C5355

Description: Cooling fan motor/3’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the connector between FM2-relay CN18-PRCB CN13 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM2 operation check PRCB CN13-6 (LOCK). 4 Change FM2. 5 Change PRCB.

Code: C5370

Description: MFP control board cooling fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the FM7 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM7 operation check MFPB PJ26-3 (LOCK). 4 Change FM17. 5 Change MFPB.

Code: C5372

Description: MFP control board CPU temperature failure
• Temperature failure of CPU on the MFP board was detected.
Remedy: 1 Reboot the machine. 2 Check the fan connector for proper connection and correct as necessary. 3 Check the fan for possible overload and correct as necessary. 4 Fan motor operation check MFPB PJ20 L-24. 5 Change MFPB.

Code: C5501

Description: AC signal abnormality
• Signal is not detected for a given period of interval when AC frequency is measured with the power switch ON or when fusing heater is turned ON/OFF.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU and PRCB for proper connection and correct or change as necessary. 3 Change fusing unit. 4 Change PRCB. 5 Change DCPU.

Code: C5601

Description: Engine control malfunction
• Engine control malfunction is detected with port monitor control.
Remedy: 1 Check the connectors on the PRCB for proper connection and correct or change as necessary. 2 Rewrite the firmware. 3 Change PRCB.