Description: Fusing abnormally high temperature detection (pressurizing side)
• The fusing pressure roller thermistor continues to detect a temperature higher than a predetermined one for a predetermined period of time.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, MFPB and DCPU for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change IHPU. 6 Change PRCB. 7 Change DCPU.
Description: Fusing abnormally high temperature detection (soaking side)
• The soaking roller thermistor/1 continues to detect a temperature higher than a predetermined one for a predetermined period of time. • The signal is turned ON to activate the hard ratchet on the soaking side.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, MFPB and DCPU for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change IHPU. 6 Change PRCB. 7 Change DCPU.
Description: Fusing abnormally high temperature detection (NS sensor)
• The NC sensor continues to detect a temperature higher than a predetermined one for a predetermined period of time.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, MFPB and REDB for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change IHPU. 6 Change PRCB. 7 Change REDB.
Description: Fusing abnormally low temperature detection (Edge of the heating roller)
• The heating roller thermistor/2 continues to detect a temperature lower than a predetermined one for a predetermined period of time.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, PRCB and REDB for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change IHPU. 6 Change PRCB. 7 Change REDB.
Description: Fusing abnormally low temperature detection (pressurizing side)
• The fusing pressure roller thermistor continues to detect a temperature lower than a predetermined one for a predetermined period of time.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, PRCB and DCPU for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change IHPU. 6 Change PRCB. 7 Change DCPU.
Description: Fusing abnormally low temperature detection (soaking side)
• The soaking roller thermistor/1 continues to detect a temperature lower than a predetermined one for a predetermined period of time.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, PRCB and DCPU for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change IHPU. 6 Change PRCB. 7 Change DCPU.
Description: Fusing abnormally low temperature detection (NC sensor)
• The NC sensor continues to detect a temperature lower than a predetermined one for a predetermined period of time.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, PRCB and REDB for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change IHPU. 6 Change PRCB. 7 Change REDB.
Description: Fusing sensor wire breaks detection (Center of the heating roller)
• At the warm-up stage, the heating roller thermistor/3 voltage does not decrease by predetermined steps (temperature rise) within a predetermined time.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, PRCB and REDB for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change IHPU. 6 Change PRCB. 7 Change REDB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.