Remedy: 1 Clean the TCR sensor window on the underside of the imaging unit if dirty. 2 M9, M10, M11 operation check M9: PRCB CN16PRCB-1 to 4 M10: PRCB CN16PRCB-5 to 8 M11: PRCB CN16PRCB-9 to 12 C-22 to 23. 3 Reinstall imaging unit. 4 Change imaging unit. 5 Change PRCB.
Code: C255C
Description: Black TCR sensor adjustment failure
Remedy: 1 Clean or correct each contact of the imaging unit if faulty. 2 M12 operation check PRCB CN16PRCB-13 to 16 C-22. 3 Reinstall imaging unit /K. 4 Change imaging unit /K. 5 Change PRCB.
Code: C2650
Description: Main backup media access error
• Contact the responsible people of KMBT before taking some countermeasures.
Remedy: 1 Check the connector (CN23PRCB) on PRCB, the connector (CN1SV ERB) on SV ERB, and the harness between the boards for proper connection and correct as necessary. 2 Change PRCB 1. Turn OFF the main power switch and replace the current PRCB with a new one. (When using a PRCB of another machine in service, be sure to use a PRCB installed in the same model.) 2. Update the PRCB firmware. 3. After completing the firmware update, turn OFF and ON the main power switch and check to see that warm-up is started. Make sure that malfunction codes other than C2650 or improper IU/TC placement is not detected. 4. When the trouble cannot be solved, reinstall the removed PRCB to the original board. NOTE • When taking the above steps, check whether PRCB is defective or not without replacing the SV ERB. 3 Change SV ERB 1. Replace the current SV ERB with a new one. 2. Turn ON the main power switch and check to see that warm-up is started. (One minute is spent to prepare the new SV ERB for use. During the period, the control panel backlight stays off.) Make sure that malfunction codes other than C2650 or improper IU/TC placement is not detected. 3. Make the specified readjustments. 4 If the above actions do not solve the problem, contact KMBT.
Code: C2651
Description: EEPROM access error (IU C)
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error. • The error was found when reading out the counter value.
Remedy: 1 Clean the connection between the imaging unit and the machine if dirty. 2 Reinstall imaging unit. 3 Check the harness for proper connection and correct as necessary. 4 Change imaging unit. 5 Change PRCB.
Code: C2652
Description: EEPROM access error (IU M)
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error. • The error was found when reading out the counter value.
Remedy: 1 Clean the connection between the imaging unit and the machine if dirty. 2 Reinstall imaging unit. 3 Check the harness for proper connection and correct as necessary. 4 Change imaging unit. 5 Change PRCB.
Code: C2653
Description: EEPROM access error (IU Y)
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error. • The error was found when reading out the counter value.
Remedy: 1 Clean the connection between the imaging unit and the machine if dirty. 2 Reinstall imaging unit. 3 Check the harness for proper connection and correct as necessary. 4 Change imaging unit. 5 Change PRCB.
Code: C2654
Description: EEPROM access error (IU K)
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error. • The error was found when reading out the counter value.
Remedy: 1 Clean the connection between the imaging unit and the machine if dirty. 2 Reinstall imaging unit. 3 Check the harness for proper connection and correct as necessary. 4 Change imaging unit. 5 Change PRCB.
Code: C2A01
Description: EEPROM access error (TC C)
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error. • The error was found when reading out the counter value.
Remedy: 1 Clean the connection between the toner cartridge and the machine if dirty. 2 Reinstall toner cartridge. 3 Check the harness for proper connection and correct as necessary. 4 Change toner cartridge. 5 Check that CN29 harness on PRCB has a ferrite core. If not, attach the ferrite core to the harness. 6 Change PRCB.