Description: Transfer belt pressure welding alienation
• At the completion of transfer belt pressure/ retraction operations, the pressure welding alienation sensor/K or the pressure welding alienation sensor/color is not in the status corresponding to each of the transfer belt pressure/retraction operations. See the table below. • Even after a predetermined period of time has elapsed since the transfer belt starts pressure/retraction operation, the pressure welding alienation sensor/K or the pressure welding alienation sensor/color is not in the status corresponding to each of the transfer belt pressure/retraction operations. See the table below. Operation Position Sensor status (K: Color) • Color and K retraction - K pressure • Color and K pressure - K pressure ON (not blocked) :OFF (blocked) pressure • Color and K retraction - Color and K pressure • K pressure - Color and K pressure Color and K pressure ON (not blocked):ON (not blocked) • K pressure - Color and K retraction • Color and K pressure -Color and K Color and K retraction OFF (blocked): OFF (blocked)
Remedy: 1 Check the M21 connector for proper connection and correct as necessary. 2 PS51 I/O check, sensor check PRCB CN11PRCB-12 (ON) K-2. 3 PS52 I/O check, sensor check PRCB CN11PRCB-15 (ON) K-2. 4 M21 operation check PRCB CN17PRCB-1 to 4 K-2. 5 Change M21. 6 Change MFPB.
Code: C2160
Description: PC charge (C) malfunction
• When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time. In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed. Then the trouble code corresponding to the IU color is displayed.
Remedy: 1 Check the imaging unit for proper connection and correct as necessary. 2 Check the HV1 connector for proper connection and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 Change IU. 5 Change HV1. 6 Change PRCB.
Code: C2161
Description: PC charge (M) malfunction
• When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time. In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed. Then the trouble code corresponding to the IU color is displayed.
Remedy: 1 Check the imaging unit for proper connection and correct as necessary. 2 Check the HV1 connector for proper connection and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 Change IU. 5 Change HV1. 6 Change PRCB.
Code: C2162
Description: PC charge (Y) malfunction
• When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time. In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed. Then the trouble code corresponding to the IU color is displayed.
Remedy: 1 Check the imaging unit for proper connection and correct as necessary. 2 Check the HV1 connector for proper connection and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 Change IU. 5 Change HV1. 6 Change PRCB.
Code: C2163
Description: PC charge (K) malfunction
• When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time. In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed. Then the trouble code corresponding to the IU color is displayed.
Remedy: 1 Check the imaging unit for proper connection and correct as necessary. 2 Check the HV1 connector for proper connection and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 Change IU. 5 Change HV1. 6 Change PRCB.
Code: C2164
Description: PC charge malfunction
• When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time. In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed. Then the trouble code corresponding to the IU color is displayed.
Remedy: 1 Check the imaging unit for proper connection and correct as necessary. 2 Check the HV1 connector for proper connection and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 Change IU. 5 Change HV1. 6 Change PRCB.
Code: C2204
Description: Waste toner agitating motor’s failure to turn
• The waste toner agitating motor lock sensor continues to be blocked or unblocked for a predetermined period of time when the motor is turning.
Remedy: 1 Change the waste toner box. 2 Check the M20 connector for proper connection and correct as necessary. 3 Check the connector of motor for proper drive coupling and correct as necessary. 4 M20 operation check PRCB CN15PRCB-11 to 14 C-12. 5 Change M20. 6 Change PRCB.
Code: C2253
Description: Color PC drum motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Remedy: 1 Check the M16 connector for proper connection and correct as necessary. 2 Check the M16 connector for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M16 operation check PRCB CN12PRCB-9 (REM) PRCB CN12PRCB-12 (LOCK) K-9. 5 Change M16. 6 Change PRCB.