Description: K PC drum motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the M18 connector for proper connection and correct as necessary. 2 Check the M18 connector for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M18 operation check PRCB CN13PRCB-15 (REM) PRCB CN13PRCB-18 (LOCK) K-10. 5 Change M18. 6 Change PRCB.
Description: K toner suction fan motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Remedy: 1 Check the FM8 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM8 operation check PRCB CN10PRCB-10 (REM) PRCB CN10PRCB-12 (LOCK) K-5. 4 Change FM8. 5 Change PRCB.
Description: Color toner suction fan motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Remedy: 1 Check the FM7 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM7 operation check PRCB CN10PRCB-7 (REM) PRCB CN10PRCB-9 (LOCK) K-5. 4 Change FM7. 5 Change PRCB.
Description: IU cooling fan motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Remedy: 1 Check the FM15 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM15 operation check REYB PH CN5REYB PH-1 (REM) REYB PH CN5REYB PH-3 (LOCK) B-7. 4 Change FM15. 5 Change REYB/PH. 6 Change PRCB.
Description: Rear side cooling fan motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Remedy: 1 Check the FM16 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM16 operation check PRCB CN26PRCB-2 (REM) PRCB CN26PRCB-3 (LOCK) C-16. 4 Change FM16. 5 Change PRCB.
Description: Release new transfer belt unit
• A new installation is not detected when a new transfer cleaner unit (image transfer belt unit) is installed.
Remedy: 1 Reinstall unit. 2 Check there is a short circuit in the fuse of the transfer belt unit. 3 Check the PRCB connector for proper connection and correct as necessary. 4 Change PRCB.
Description: Abnormally low toner density detected cyan TCR sensor
• When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper.
Remedy: 1 Perform image troubleshooting procedure if image density is low. 2 Clean the TCR sensor window on the underside of the imaging unit if dirty 3 Reinstall imaging unit. 4 Reinstall toner cartridge. 5 M9, M10, M11 operation check (At this time, IU must be non-installation.) M9: PRCB CN16PRCB-1 to 4 M10: PRCB CN16PRCB-5 to 8 M11: PRCB CN16PRCB-9 to 12 C-22 to 23. 6 M13, M14 operation check M13: PRCB CN17PRCB-5 to 8 M14: PRCB CN17PRCB-9 to 12 K-1. 7 If the toner empty sensor and its surroundings inside the sub hopper are dirtied with toner, clean them. 8 Change imaging unit. 9 Change PRCB.
Description: Abnormally high toner density detected cyan TCR sensor
• TC ratio in the developing unit which is determined by Toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively.
Remedy: 1 Clean the TCR sensor window on the underside of the imaging unit if dirty. 2 Reinstall imaging unit. 3 Reinstall toner cartridge. 4 Change imaging unit. 5 Change PRCB. 6 Change sub hopper unit.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.