Code: C6753

Description: ASIC clock input error (back side)
• When starting the scanner, verification on reading and writing the predetermined value for image processing ASIC on CCD board was conducted, and verification failure was detected.
Causes: Exposure unit CCD board (CCDB) MFP board (MFPB)
Remedy: 1 Correct the harness connection of CCDB if faulty. - - 2 Change CCDB - - 3 Change MFPB

Code: C6754

Description: CIS clamp adjustment failure
• After the gain adjustment is performed at the start-up, the CIS clamp adjustment value is too high or too low.
Causes: CIS module (CIS) DS image processing board (DSIPB) CIS inverter board (CINVB) CIS power supply (CISPU) MFP board (MFPB)
Remedy: 1 Correct the harness connection between CIS and DSIPB if faulty. - - 2 Correct the harness connection between CIS and CINVB if faulty. - - 3 Correct the harness connection between CIS and CISPU if faulty. - - 4 Check for possible extraneous light and correct as necessary. - - 5 Clean the back side reading glass and the shading sheet if dirty. - - 6 Change CIS - - 7 Change DSIPB - - 8 Change CINVB - - 9 Change CISPU - - 10 Change MFPB

Code: C6755

Description: CIS gain adjustment failure
• After the gain adjustment is performed at the start-up, the peak value of the output data is lower than a given value.
Causes: CIS module (CIS) DS image processing board (DSIPB) CIS inverter board (CINVB) CIS power supply (CISPU) MFP board (MFPB)
Remedy: 1 Correct the harness connection between CIS and DSIPB if faulty. - - 2 Correct the harness connection between CIS and CINVB if faulty. - - 3 Correct the harness connection between CIS and CISPU if faulty. - - 4 Check for possible extraneous light and correct as necessary. - - 5 Clean the back side reading glass and the shading sheet if dirty. - - 6 Change CIS - - 7 Change DSIPB - - 8 Change CINVB - - 9 Change CISPU - - 10 Change MFPB

Code: C6901

Description: DSC board mount failure 1
• When MFP detects that DSC board (front side) is not properly installed.
Causes: DSC board (SC-507) MFP board (MFPB)
Remedy: 1 Correct the harness connection of DSC board if faulty. - - 2 Change DSC board - - 3 Change MFPB

Code: C6902, C6903

Description: DSC Bus check NG1
• When DSC bus check (front side) detects an error.
Causes: DSC board (SC-507) MFP board (MFPB)
Remedy: 1 Correct the harness connection of DSC board if faulty. - - 2 Change DSC board - - 3 Change MFPB

Code: C6911

Description: DSC board mount failure 2
• When MFP detects that DSC board (back side) is not properly installed.
Causes: DSC board (SC-507) MFP board (MFPB)
Remedy: 1 Correct the harness connection of DSC board if faulty. - - 2 Change DSC board - - 3 Change MFPB

Code: C6912, C6913

Description: DSC Bus check NG2
• When DSC bus check (back side) detects an error.
Causes: DSC board (SC-507) MFP board (MFPB)
Remedy: 1 Correct the harness connection of DSC board if faulty. - - 2 Change DSC board - - 3 Change MFPB

Code: C6F01

Description: Scanner sequence trouble 1
• The original transport interval becomes shorter than the designed value due to an original transport control error in original reading in ADF.
Causes: MFP board (MFPB) DF control board (DFCB)
Remedy: 1 Correct the harness connection between main body and ADF if faulty. - - 2 Change DFCB - - 3 Change MFPB