Description: CCD clamp/gain adjustment failure • The adjustment value is 0 or 255 during a CCD clamp adjustment. • The peak value of the output data is 64 or less during a CCD gain adjustment.
Causes: • LED exposure unit (LA201) • CCD board (CCDB) • MFP board (MFPB)
Remedy: 1 Correct the harness connection between CCDB and MFPB if faulty. 2 Check for possible extraneous light and correct as necessary. 3 Clean the lens, mirrors, CCD surface, and shading sheet if dirty. 4 Correct reflective mirror of the scanner if faulty, or change scanner mirror. 5 Replace CCDB. 6 Replace MFPB.
Code: C6752
Description: ASIC clock input error (front side) When starting the machine, verification on reading and writing the predetermined value for image processing ASIC on CCD board was conducted, and verification failure was detected.
Causes: • CCD board (CCDB) • MFP board (MFPB)
Remedy: 1 Correct the harness connection of CCDB if faulty. 2 Replace CCDB. 3 Replace MFPB.
Code: C6753
Description: ASIC clock input error (back side) When starting the machine, verification on reading and writing the predetermined value for image processing ASIC on dual scan image processing board was conducted, and verification failure was detected.
Remedy: 1 Correct the harness connection between DF and DSIPB if faulty. 2 Correct the harness connection between DSIPB and MFPB if faulty. 3 Replace the CIS module. 4 Replace DSIPB. 5 Replace MFPB.
Code: C6754
Description: CIS clamp adjustment failure After the gain adjustment is performed at the start-up, the CIS clamp adjustment value is too high or too low.
Remedy: 1 Correct the harness connection between CIS and DSIPB if faulty. 2 Correct the harness connection between CIS and DFPU if faulty. 3 Check for possible extraneous light and correct as necessary. 4 Clean the back side reading glass and the shading sheet if dirty. 5 Replace CIS. 6 Replace DSIPB. 7 Replace DFPU. 8 Replace MFPB.
Code: C6755
Description: CIS gain adjustment failure After the gain adjustment is performed at the start-up, the peak value of the output data is lower than a given value.
Remedy: 1 Correct the harness connection between CIS and DSIPB if faulty. 2 Correct the harness connection between CIS and DFPU if faulty. 3 Check for possible extraneous light and correct as necessary. 4 Clean the back side reading glass and the shading sheet if dirty. 5 Replace CIS. 6 Replace DSIPB. 7 Replace DFPU. 8 Replace MFPB.
Code: C6901
Description: DSC board mount failure 1 When MFP detects that DSC board (front side) is not properly installed.