Code: C6911

Description: DSC board mount failure 2
When MFP detects that DSC board (back side) is not properly installed.
Causes: • DSC board/2 (DSCB/2; SC-508) • Dual scan image processing board (DSIPB) • MFP board (MFPB)
Remedy: 1 Correct the harness connection of DSC board if faulty. 2 Replace the DSC board. 3 Replace MFPB.

Code: C6912

Description: DSC Bus check NG2-1
When DSC bus check (back side) detects an error.
Causes: • DSC board/2 (DSCB/2; SC-508) • Dual scan image processing board (DSIPB) • MFP board (MFPB
Remedy: 1 Correct the harness connection of DSC board if faulty. 2 Replace the DSC board. 3 Replace MFPB.

Code: C6913

Description: DSC Bus check NG2-2
When DSC bus check (back side) detects an error.
Causes: • DSC board/2 (DSCB/2; SC-508) • Dual scan image processing board (DSIPB) • MFP board (MFPB
Remedy: 1 Correct the harness connection of DSC board if faulty. 2 Replace the DSC board. 3 Replace MFPB.

Code: C6F01

Description: Scanner sequence trouble 1
The original transport interval becomes shorter than the designed value due to an original transport control error in original reading in DF.
Causes: • MFP board (MFPB) • DF control board (DFCB)
Remedy: 1 Correct the harness connection between main body and DF if faulty. 2 Replace DFCB. 3 Replace MFPB.

Code: C8101

Description: Before reading pressure/retraction alienation mechanism
• During a pressure motion being performed, the before read sensor (PS6) output does not change from H to L. • During a retraction motion being performed, the before read sensor (PS6) output does not change from L to H.
Causes: • Reading roller pressure/retraction motor (M6) • Before read sensor (PS6) • DF control board (DFCB)
Remedy: 1 Check the connector between M6-DFCB CN4 for proper connection, and correct as necessary. 2 Check the connector of M6 for proper drive coupling, and correct as necessary. 3 Check the connector between PS6-DFCB CN9 for proper connection, and correct as necessary. 4 PS6 I/O check, sensor check DFCB CN9-5 (ON) DF-702 3-C. 5 M6 operation check DFCB CN4-20 (ON) DF-702 10-C. 6 Replace M6. 7 DFCB ICP9 conduction check. 8 Replace DFCB.

Code: C8103

Description: Lift up mechanism trouble (Upward movement)
The lift up upper sensor (PS2) is not unblocked after a lapse of a given time after the lift-up motor (M5) moves up (is turned forward).
Causes: • Lift-up motor (M5) • Lift-up upper sensor (PS2) • DF control board (DFCB)
Remedy: 1 Check the connector between M5-DFCB CN11 for proper connection, and correct as necessary. 2 Check the connector of M5 for proper drive coupling, and correct as necessary. 3 Check the connector between PS2-DFCB CN5 for proper connection, and correct as necessary. 4 PS2 I/O check, sensor check DFCB CN5-3 (ON) DF-702 10-C. 5 M5 operation check DFCB CN11-4 to 7 DF-702 13-C. 6 Replace M5. 7 DFCB ICP13 conduction check. 8 Replace DFCB.

Code: C8106

Description: Lift up mechanism failure (Downward movement)
The lift up lower sensor (PS3) is not blocked after a lapse of a given time after the lift-up motor (M5) goes down (is turned backward).
Causes: • Lift-up motor (M5) • Lift-up lower sensor (PS3) • DF control board (DFCB)
Remedy: 1 Check the connector between M5-DFCB CN11 for proper connection, and correct as necessary. 2 Check the connector of M5 for proper drive coupling, and correct as necessary. 3 Check the connector between PS3-DFCB CN12 for proper connection, and correct as necessary. 4 PS3 I/O check, sensor check DFCB CN12-12 (ON) DF-702 12-C. 5 M5 operation check DFCB CN11-4 to 7 DF-702 13-C. 6 Replace M5. 7 DFCB ICP13 conduction check. 8 Replace DFCB.

Code: C8107

Description: Glass cleaning mechanism trouble
The front side cleaning home sensor (PS18) is not unblocked after the set period of time has elapsed after the front side cleaning motor (M8) is turned ON.
Causes: • Front side cleaning motor (M8) • Front side cleaning home sensor (PS18) • DF control board (DFCB)
Remedy: 1 Check the connector between M8-DFCB CN6 for proper connection and correct as necessary. 2 Check the connector between PS18-DFCB CN3 for proper connection and correct as necessary. 3 Check the connector of M8 for proper drive coupling, and correct as necessary. 4 PS18 I/O check, sensor check DFCB CN3-6 (ON) DF-702 6-C. 5 M8 operation check DFCB CN6-1 to 4 DF-702 7-C. 6 Replace M8. 7 Replace DFCB.