Description: Main unit backup data miscompare The replacement of the printer control board is detected.
Causes: • Printer control board (PRCB)
Remedy: 1 1.1. Check that the trouble code C4802 appears and then display service mode. 1.2. Call the Enhanced Security to the screen. 1.3. Touch [Engine Data Backup]. 1.4. Touch [Engine Data Load mode], and press the Start key. 1.5. Select [Yes], and press the Start key again. 1.6. Check that the result OK appears. 1.7. Turn OFF the main power switch and turn it ON again more than 10 seconds after. 2 Update the PRCB firmware. 3 If the above actions do not solve the problem, contact KMBT.
Description: Transfer belt motor's failure to turn The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Causes: • Transfer belt motor (M1) • Printer control board (PRCB)
Remedy: 1 Check the connector between M1-PRCB CN21 for proper connection and correct as necessary. 2 Check the transfer belt for proper drive coupling and correct as necessary. 3 M1 operation check PRCB CN21-3 (REM) PRCB CN21-6 (LOCK) 17-K. 4 Replace M1. 5 PRCB ICP7 or ICP18 conduction check. 6 Replace PRCB.
Description: Transfer belt motor's turning at abnormal timing The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary
Causes: • Transfer belt motor (M1) • Printer control board (PRCB)
Remedy: 1 Check the connector between M1-PRCB CN21 for proper connection and correct as necessary. 2 Check the transfer belt for proper drive coupling and correct as necessary. 3 M1 operation check PRCB CN21-3 (REM) PRCB CN21-6 (LOCK) 17-K. 4 Replace M1. 5 PRCB ICP7 or ICP18 conduction check. 6 Replace PRCB.
Description: IH power supply cooling fan's failure to turn The fan lock signal remains HIGH for a predetermined continuous period of time while the fan remains stationary.
Causes: • IH power supply cooling fan (FM10) • Printer control board (PRCB)
Remedy: 1 Check the connector between FM10-relay CN293- PRCB CN5 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM10 operation check PRCB CN5-3 (DRIVE) PRCB CN5-5 (LOCK) 9-K. 4 Replace FM10. 5 PRCB ICP24 conduction check. 6 Replace PRCB.
Description: IH coil cooling fan's failure to turn The fan lock signal remains HIGH for a predetermined continuous period of time while the fan remains stationary.
Causes: • IH coil cooling fan (FM3) • Printer control board (PRCB)
Remedy: 1 Check the connector between FS3-relay CN324-PRCB CN2 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM3 operation check PRCB CN2-8 (DRIVE) PRCB CN2-9 (LOCK) 3-K. 4 Replace FM3. 6 Replace PRCB.
Description: DC power supply cooling fan's failure to turn The fan lock signal remains HIGH for a predetermined continuous period of time while the fan remains stationary.
Causes: • DC power supply cooling fan (FM9) • DC power supply (DCPU) • Printer control board (PRCB)
Remedy: 1 Check the connector between FM9-relay CN333- PRCB CN38 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM9 operation check PRCB CN38-1 (DRIVE) PRCB CN38-3 (LOCK) 19-K. 4 Replace FM9. 5 PRCB ICP3 conduction check. 6 Replace DCPU. 7 Replace PRCB.
Description: Ozone ventilation fan's failure to turn The fan lock signal remains HIGH for a predetermined continuous period of time while the fan remains stationary.
Causes: • Ozone ventilation fan motor (FM6) • Printer control board (PRCB)
Remedy: 1 Check the connector between FM6-relay CN322- PRCB CN1 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM6 operation check PRCB CN1-6 (DRIVE) PRCB CN1-8 (LOCK) 7-K. 4 Replace FM6. 5 Replace PRCB.
Description: Toner bottle cooling fan's failure to turn The fan lock signal remains HIGH for a predetermined continuous period of time while the fan remains stationary
Causes: • Toner bottle cooling fan (FM16) • Printer control board (PRCB)
Remedy: 1 Check the connector between FM16-relay CN328- PRCB CN2 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM16 operation check PRCB CN2-1 (DRIVE) PRCB CN2-3 (LOCK) 2-K. 4 Replace FM16. 5 Replace PRCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.