Description: Paper feed assist fan /Rr2 (FM24) rotation abnormality. The FM24 EM error detection signal is detected twice in succession within a specified period of time after FM24 was turned ON. However, error detection signal (24V cut off) is not detected.
Causes: • Paper feed assist fan / Rr2 (FM24) • Printer control board (PRCB)
Remedy: 1. Check the connector connection and the wiring between PRCB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: Main body (3/4): 23-A) 3. Replace FM24. 4. Replace PRCB.
Description: Paper feed assist fan /Fr2 (FM23) rotation abnormality + 24V power abnormality. The FM23 EM error detection signal is detected twice in succession within a specified period of time after FM23 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: • DC power supply /2 (DCPS/2) • Printer control board (PRCB)
Remedy: 1. Check the connector connection and the wiring between PRCB and DCPS /2, and repair it if any abnormality. 2. Replace DCPS /2 3. Replace PRCB.
Description: Paper feed assist fan /Fr2 (FM23) rotation abnormality. The FM23 EM error detection signal is detected twice in succession within a specified period of time after FM23 was turned ON. However, error detection signal (24V cut off) is not detected.
Causes: • Paper feed assist fan / Fr2 (FM23) • Printer control board (PRCB)
Remedy: 1. Check the connector connection and the wiring between PRCB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: Main body (3/4): 23-A) 3. Replace FM23. 4. Replace PRCB.
Description: 1st tandem PF-703/706 paper feed assist fan /Fr1 (FM1) power abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • Paper feed assist fan / Fr1 (FM1: PF-703/706) • PF drive board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 6-F, PF-706: 4-C) 3. Replace FM1 and PFUDB.
Description: 1st tandem PF-703/706 paper feed assist fan /Fr1 (FM1) rotation abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Paper feed assist fan / Fr1 (FM1: PF-703/706) • PF drive board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and FM1, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 6-F, PF-706: 4-C) 3. Replace FM1. 4. Replace PFUDB.
Description: 1st tandem PF-703/706 paper feed assist fan /Rr1 (FM2) power abnormality. The EM error detection signal of FM2 is detected twice in succession within a specified period of time after FM2 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • Paper feed assist fan / Rr1 (FM2: PF-703/ PF-706) • printer control board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 6-F) 3. Replace FM2 and PFUDB.
Description: 1st tandem PF-703/706 paper feed assist fan /Rr1 (FM2) rotation abnormality. The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Paper feed assist fan / Fr1 (FM2: PF-703/ PF-706) • PF drive board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 6-F) 3. Replace FM2. 4. Replace PFUDB.
Description: 1st tandem PF-703/706 paper feed assist fan /Fr2 (FM5: PF-703, FM3: PF-706) power abnormality. The FM5 EM and FM3 EM error detection signals are detected twice in succession within a specified period of time after FM5 and FM3 were turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • Paper feed assist fan / Fr2 (FM5: PF-703) • Paper feed assist fan / Fr2 (FM3: PF-706) • PF drive board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 10-F, PF-706: 7-C) 3. Replace FM5 and PFUDB at a time: PF-703 Replace FM3 and PFUDB at a time: PF-706
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.