Code: C-0348

Description: 1st tandem PF-703/706 paper feed assist fan /Fr2 (FM5: PF-703, FM3: PF-706) rotation abnormality. The FM5 EM and FM3 EM error detection signals are detected twice in succession within a specified period of time after FM5 and FM3 were turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Paper feed assist fan / Fr2 (FM5: PF-703) • Paper feed assist fan / Fr2 (FM3: PF-706 ) • PF drive board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 10-F, PF-706: 7-C) 3. Replace FM5: PF-703 Replace FM3: PF-706 4. Replace PFUDB.

Code: C-0350

Description: 1st tandem PF-703/706 paper feed assist fan /Rr2 (FM6: PF-703, FM4: PF-706) power abnormality. The FM6 EM and FM4 EM error detection signals are detected twice in succession within a specified period of time after FM6 and FM4 were turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • Paper feed assist fan / Rr2 (FM6: PF-703) • Paper feed assist fan / Rr2 (FM4: PF-706) • PF drive board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 11-F, PF-706: 7-C) 3. Replace FM6 and PFUDB at a time: PF-703 Replace FM4 and PFUDB at a time: PF-706 4. Replace PFUDB.

Code: C-0351

Description: 1st tandem PF-703/706 paper feed assist fan /Rr2 (FM6: PF-703, FM4: PF-706) rotation abnormality. The FM6 EM and FM4 EM error detection signals are detected twice in succession within a specified period of time after FM6 and FM4 were turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Paper feed assist fan / Rr2 (FM6: PF-703) • Paper feed assist fan / Rr2 (FM4: PF-706) • PF drive board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 11-F, PF-706: 7-C) 3. Replace FM6: PF-703 Replace FM4: PF-706 4. Replace PFUDB.

Code: C-0353

Description: 1st tandem PF-703/706 paper feed assist fan /Fr3 (FM9: PF-703, FM5: PF-706) power abnormality. The FM9 EM and FM5 EM error detection signals are detected twice in succession within a specified period of time after FM9 and FM5 were turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • Paper feed assist fan / Fr3 (FM9: PF-703) • Paper feed assist fan / Fr3 (FM5: PF-706) • PF drive board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 18-F, PF-706: 9-C) 3. Replace FM9 and PFUDB at a time: PF-703 Replace FM5 and PFUDB at a time: PF-706

Code: C-0354

Description: 1st tandem PF-703/706 paper feed assist fan /Fr3 (FM9: PF-703, FM5: PF-706) rotation abnormality. The FM9 EM and FM5 EM error detection signals are detected twice in succession within a specified period of time after FM9 and FM5 were turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Paper feed assist fan / Fr3 (FM9: PF-703) • Paper feed assist fan / Fr3 (FM5: PF-706) • PF drive board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 18-F, PF-706: 9-C) 3. Replace FM9: PF-703 Replace FM5: PF-706 4. Replace PFUDB.

Code: C-0356

Description: 1st tandem PF-703/706 paper feed assist fan /Rr3 (FM10: PF-703, FM6: PF-706) power abnormality. The FM10 EM and FM6 EM error detection signals are detected twice in succession within a specified period of time after FM10 and FM6 were turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • Paper feed assist fan / Rr3 (FM10: PF-703) • Paper feed assist fan / Rr3 (FM6: PF-706) • PF drive board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 19-F, PF-706: 9-C) 3. Replace FM10 and PFUDB at a time: PF-703 Replace FM6 and PFUDB at a time: PF-706

Code: C-0357

Description: 1st tandem PF-703/706 paper feed assist fan /Rr3 (FM10: PF-703, FM6: PF-706) rotation abnormality. The FM10 EM and FM6 EM error detection signals are detected twice in succession within a specified period of time after FM10 and FM6 were turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Paper feed assist fan / Rr3 (FM10: PF-703) • Paper feed assist fan / Rr3 (FM6: PF-706) • PF drive board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 19-F, PF-706: 9-C) 3. Replace FM10: PF-703 Replace FM6: PF-706 4. Replace PFUDB.

Code: C-0359

Description: 1st tandem PF-703/706 cooling fan power abnormality. PF-703: The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. At this time, an error detection signal (blowout of ICP) is detected. PF-706: The FM7 EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan (FM7) was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • PF cooling fan /1 (FM19: PF-703) • PF cooling fan (FM7: PF-706 ) • PF cooling fan /2 (FM20: PF-703) • PF drive board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 22-F, 23-F, PF-706: 8-H) 3. Replace FM7 and PFUDB at a time: PF-706