Description: PI-PFU (PF-703) paper feed assist fan /Rr2 (FM6) rotation abnormality. The FM6EM error detection signal is detected twice in succession within a specified period of time after FM6 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • paper feed assist fan / Rr2 (FM6: PF-703) • Paper feed assist fan / Rr2 (FM4: PF-706) • PF drive board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 11-F, PF-706: 7-C) 3. Replace FM6: PF-703 Replace FM4: PF-706 4. Replace PFUDB.
Description: PI-PFU (PF-703) paper feed assist fan /Fr3 (FM9) power abnormality. The FM9EM error detection signal is detected twice in succession within a specified period of time after FM9 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • paper feed assist fan / Fr3 (FM9: PF-703) • Paper feed assist fan / Fr3 (FM5: PF-706) • PF drive board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 18-F, PF-706: 9-C) 3. Replace FM9 and PFUDB at a time: PF-703 Replace FM5 and PFUDB at a time: PF-706
Description: PI-PFU (PF-703) paper feed assist fan /Fr3 (FM9) rotation abnormality. The FM9EM error detection signal is detected twice in succession within a specified period of time after FM9 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • paper feed assist fan / Fr3 (FM9: PF-703) • Paper feed assist fan / Fr3 (FM5: PF-706) • PF drive board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 18-F, PF-706: 9-C) 3. Replace FM9: PF-703 Replace FM5: PF-706 4. Replace PFUDB.
Description: PI-PFU (PF-703) paper feed assist fan /Rr3 (FM10) power abnormality. The EM error detection signal of FM10 is detected twice in succession within a specified period of time after FM10 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • paper feed assist fan / Rr3 (FM10: PF-703) • Paper feed assist fan / Rr3 (FM6: PF-706) • PF drive board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 19-F, PF-706: 9-C) 3. Replace FM10 and PFUDB at a time: PF-703 Replace FM6 and PFUDB at a time: PF-706
Description: PI-PFU (PF-703) paper feed assist fan /Rr3 (FM10) rotation abnormality. The FM10EM error detection signal is detected twice in succession within a specified period of time after FM10 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • paper feed assist fan / Rr3 (FM10: PF-703) • Paper feed assist fan / Rr3 (FM6: PF-706) • PF drive board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 19-F, PF-706: 9-C) 3. Replace FM10: PF-703 Replace FM6: PF-706 4. Replace PFUDB.
Description: PI-PFU (PF-703) cooling fan power abnormality. The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • PF cooling fan (FM7: PF-706) • PF cooling fan /1 (FM19: PF-703) • PF cooling fan /2 (FM20: PF-703) • PF drive board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 22-F, 23-F, PF-706: 8-H) 3. Replace FM19, FM20 and PFUDB at a time: PF-703 Replace FM7 and PFUDB at a time: PF-706
Description: PI-PFU (PF-703) cooling fan rotation abnormality 1. The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • PF cooling fan (FM7: PF-706) • PF cooling fan /1 (FM19: PF-703) • PF cooling fan /2 (FM20: PF-703) • PF drive board (PFUDB: PF-703/706)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 22-F, 23-F, PF-706: 8-H) 3. Replace FM19, FM20 and PFUDB at a time: PF-703 Replace FM7 and PFUDB at a time: PF-706
Description: PI-PFU (PF-703) cooling fan rotation abnormality 2. The FM21EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan /3 (FM21) was turned ON with the front door closed. At this time, an error detection signal (blowout of ICP) is detected.
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 23-F) 3. Replace FM21 and PFUDB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.