Description: 1st tandem PF-703 paper leading edge separation fan /Fr2 (FM7) rotation abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Paper leading edge separation fan /Fr2 (FM7: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 11-F) 3. Replace FM7. 4. Replace PFUDB.
Code: C-0505
Description: 1st tandem PF-703 paper leading edge separation fan /Fr3 (FM11) power abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • Paper leading edge separation fan /Fr3 (FM11: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 19-F) 3. Replace FM11 and PFUDB.
Code: C-0506
Description: 1st tandem PF-703 paper leading edge separation fan /Fr3 (FM11) rotation abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Paper leading edge separation fan /Fr3 (FM11: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 19-F) 3. Replace FM11. 4. Replace PFUDB.
Code: C-0507
Description: 1st tandem PF-703 paper leading edge separation fan /Rr1 (FM4) power abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • Paper leading edge separation fan /Rr1 (FM4: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 6-F) 3. Replace FM4 and PFUDB.
Code: C-0508
Description: 1st tandem PF-703 paper leading edge separation fan /Rr1 (FM4) rotation abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Paper leading edge separation fan /Rr1 (FM4: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 6-F) 3. Replace FM4 4. Replace PFUDB.
Code: C-0509
Description: 1st tandem PF-703 paper leading edge separation fan /Rr2 (FM8) power abnormality. The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • Paper leading edge separation fan /Rr2 (FM8: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 11-F) 3. Replace FM8 and PFUDB.
Code: C-0510
Description: 1st tandem PF-703 paper leading edge separation fan /Rr2 (FM8) rotation abnormality. The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Paper leading edge separation fan /Rr2 (FM8: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 11-F) 3. Replace FM8. 4. Replace PFUDB.
Code: C-0511
Description: 1st tandem PF-703 paper leading edge separation fan /Rr3 (FM12) power abnormality. The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • Paper leading edge separation fan /Rr3 (FM12: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 19-F) 3. Replace FM12 and PFUDB.