Description: PI-PFU (PF-703) paper suction fan /1 (FM14) rotation abnormality. The FM14EM error detection signal is detected twice in succession within a specified period of time after FM14 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Paper suction fan /2 (FM14: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 14-L) 3. Replace FM14. 4. Replace PFUDB.
Description: PI-PFU (PF-703) paper suction fan /3 (FM16) power abnormality. The FM16 EM error detection of FM16 is detected twice in succession within a specified period of time after FM16 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • Paper suction fan /4 (FM16: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 16-L) 3. Replace FM16 and PFUDB.
Description: PI-PFU (PF-703) paper suction fan /3 (FM16) rotation abnormality. The FM16EM error detection signal is detected twice in succession within a specified period of time after FM16 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Paper suction fan /4 (FM16: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 16-L) 3. Replace FM16. 4. Replace PFUDB.
Description: PI-PFU (PF-703) paper suction fan /5 (FM18) power abnormality. The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • Paper suction fan /6 (FM18: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 19-L) 3. Replace FM18 and PFUDB.
Description: PI-PFU (PF-703) paper suction fan /5 (FM18) rotation abnormality. The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Paper suction fan /6 (FM18: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 19-L) 3. Replace FM18. 4. Replace PFUDB.
Description: 1st tandem PF-703 dehumidifier fan /Rt1 (FM22) rotation abnormality. The FM22EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan heater, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 9-B) 3. Replace the fan heater (FM22). 4. Replace PFUDB.
Description: PI-PFU (PF-703) dehumidifier fan /Lt1 (FM23) rotation abnormality. The FM23EM error detection signal is detected twice in succession within a specified period of time after FM23 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan heater, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 10-C) 3. Replace the fan heater (FM23). 4. Replace PFUDB.
Description: 1st tandem PF-703 dehumidifier fan /Rt2 (FM24) rotation abnormality. The FM24EM error detection signal is detected twice in succession within a specified period of time after FM24 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan heater, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 10-C) 3. Replace the fan heater (FM24). 4. Replace PFUDB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.