Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub PRESS 1052 — Trang 69/94

Code: C-2208

Description: Blade motor (M22) power abnormality. The blade READY signal (READY condition) cannot be detected within a specified period of time after the blade replacement signal turns ON. Or, the blade READY signal (READY release condition) cannot be detected within a specified period of time after the blade replacement signal turns OFF. At this time, an error detection signal (blowout of ICP) of the blade motor (M22) is detected.
Causes: • Blade motor (M22) • Printer control board (PRCB)
Remedy: 1. Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:Main body (3/4): 14-I) 3. Replace M22 and PRCB at a time.

Code: C-2209

Description: It is checked that the movement of the blade motor (M22) is not completed. The blade READY signal (READY condition) cannot be detected within a specified period of time after the blade replacement signal turns ON. Or, the blade READY signal (READY release condition) cannot be detected within a specified period of time after the blade replacement signal turns OFF. At this time, an error detection signal is not detected.
Causes: • Blade motor (M22) • Printer control board (PRCB)
Remedy: 1. Check the trimmer blade operation, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:Main body (3/4): 14-I) 4. Replace M22. 5. Replace PRCB.

Code: C-2210

Description: The drum motor (M2) does not start. The drum READY2 signal (READY signal) is not detected within a specified period of time after M2 turns ON.
Causes: • Drum motor (M2) • Printer control board (PRCB)
Remedy: 1. Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:Main body (3/4): 17-P) 3. Replace M2. 4. Replace PRCB.

Code: C-2211

Description: Intermediate hopper motor (M11) power abnormality. An error detection signal (blowout of ICP) is detected when M11 turns ON.
Causes: • Intermediate hopper motor (M11) • Printer control board (PRCB)
Remedy: 1. Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:Main body (3/4): 2-P) 3. Replace M11 and PRCB at a time.

Code: C-2212

Description: Air separation motor (M10) power abnormality. An error detection signal (blowout of ICP) is detected when M10 turns ON.
Causes: • Air separation motor (M10) • Printer control board (PRCB)
Remedy: 1. Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:Main body (3/4): 2-P) 3. Replace M10 and PRCB at a time.

Code: C-2213

Description: Air separation motor (M10) rotation abnormality. Since an error is detected when M10 turns ON, turn it OFF. An error is still detected when turn it ON again.
Causes: • Air separation motor (M10) • Printer control board (PRCB)
Remedy: 1. Check the air separation section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:Main body (3/4): 2-P) 4. Replace M10. 5. Replace PRCB.

Code: C-2214

Description: The toner conveyance abnormality is detected. When executing the toner supply operation for 8 minutes, the intermediate hopper toner remaining sensor (PS39) does not turn ON and the hopper toner remaining sensor /2 (PS33) detects ON in succession for 15 seconds.
Causes: • Intermediate hopper toner remaining sensor (PS39) • Hopper toner remaining sensor /2 (PS33) • Printer control board (PRCB)
Remedy: 1. Check the hopper section and the intermediate hopper section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PRCB and the sensor, and repair it if any abnormality. 3. Check the sensor, and repair/replace it if any abnormality.(Wiring diagram: Main body (3/4): 6-D, 8-P, 3-P) 4. Replace PS39. 5. Replace PS33. 6. Replace PRCB.

Code: C-2215

Description: Hopper toner remaining sensor /2 (PS33) abnormality. When the toner is supplied for 8minutes, it is found that the toner remaining sensor /1 (PS32) does not turn ON and the hopper toner remaining sensor /2 (PS33) turns OFF for the last 15 seconds in succession.
Causes: • Hopper toner remaining sensor /1 (PS32) • Hopper toner remaining sensor /2 (PS33) • Printer control board (PRCB)
Remedy: 1. Check the hopper section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PRCB and the sensor, and repair it if any abnormality. 3. Check the sensor, and repair/replace it if any abnormality.(Wiring diagram: Main body (3/4): 6-D, 7-P, 8-P) 4. Replace PS32. 5. Replace PS33. 6. Replace PRCB.