Description: The stacker tray encoder sensor (PS2) does not turn ON within a specified period of time after the stacker tray up down motor (M1) turns ON. Or, the initial operation or the stacker tray down operation is not completed within a specified period of time.
Causes: • Stacker tray up down motor (M1) • LS control board (LSCB) DIPSW6-6
Remedy: 1. Check the stacker tray up down section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:LS-505:5-A) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram:LS-505:5-A) 5. Replace PS2. 6. Replace M1. 7. Replace LSCB.
Description: The shift unit home sensor (PS11) does not turn ON within a specified period of time after the shift unit motor (M5) turns ON. Or, PS11 does not turn ON within a specified period of time.
Causes: • Shift unit motor (M5) • LS control board (LSCB) DIPSW6-6
Remedy: 1. Check the shift unit section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 6-A) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 5-H) 5. Replace PS11. 6. Replace M5. 7. Replace LSCB.
Description: The alignment plate home sensor (PS12) does not turn ON within a specified period of time after the alignment motor (M7) turns ON. Or, PS12 does not turn ON within a specified period of time.
Causes: • Alignment motor (M7) • LS control board (LSCB) DIPSW6-6
Remedy: 1. Check the alignment section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 7-A) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 5-H) 5. Replace PS12. 6. Replace M7. 7. Replace LSCB.
Description: The grip conveyance home sensor (PS5) does not turn ON within a specified period of time after the grip conveyance motor (M4) turns ON.
Causes: Grip conveyance motor (M4) DIPSW6-6
Remedy: 1. Check the grip conveyance section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 6-A) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 2-H) 5. Replace PS5. 6. Replace M4. 7. Replace LSCB.
Description: The stacker tray upper limit switch (MS2) is ON when the stacker tray up down motor (M1) is in the up operation.
Causes: • Stacker tray up down motor (M1) • Stacker tray upper limit switch (MS2) DIPSW6-6
Remedy: 1. Check the stacker tray up down section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between LSCB and motor/switch, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 5-A) 4. Check the operation of the switch, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 7-A) 5. Replace MS2. 6. Replace M1. 7. Replace LSCB.
Description: The stacker tray lower limit switch (MS3) is ON when the stacker tray up down motor (M1) is in the down operation.
Causes: • Stacker tray up down motor (M1) • Stacker tray lower limit switch (MS3) DIPSW6-6
Remedy: 1. Check the stacker tray up down section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between LSCB and motor/switch, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 5-A) 4. Check the operation of the switch, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 7-A) 5. Replace MS3. 6. Replace M1. 7. Replace LSCB.
Description: Charger cleaning motor (M23) operation time abnormality.
Causes: • Charger cleaning limit sensor (PS26) • Charger cleaning limit sensor (PS27) • Charger cleaning motor (M23) • Web motor (M24) • Printer control board (PRCB)
Remedy: 1. Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:Main body (3/4): 16-I, 3-A) 3. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: Main body (3/4): 16-I, 17-I) 4. Replace PS26 or PS27. 5. Replace M23 or M24. 6. Replace PRCB.
Description: Charger cleaning motor (M23) power abnormality.
Causes: • Charger cleaning motor (M23) • Web motor (M24) • Printer control board (PRCB)
Remedy: 1. Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:Main body (3/4): 16-I, Main body (2/4): 3-A) 3. Replace M23, M24 and PRCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.