Description: PI-PFU (PF-703) paper leading edge separation fan /Fr2 (FM7) rotation abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Paper leading edge separation fan /Fr2 (FM7: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 11-F) 3. Replace FM7. 4. Replace PFUDB.
Description: PI-PFU (PF-703) paper leading edge separation fan /Fr3 (FM11) power abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • Paper leading edge separation fan /Fr3 (FM11: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 19-F) 3. Replace FM11 and PFUDB.
Description: PI-PFU (PF-703) paper leading edge separation fan /Fr3 (FM11) rotation abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Paper leading edge separation fan /Fr3 (FM11: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 19-F) 3. Replace FM11. 4. Replace PFUDB.
Description: PI-PFU (PF-703) paper leading edge separation fan /Rr1 (FM4) power abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • Paper leading edge separation fan /Rr1 (FM4: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 6-F) 3. Replace FM4 and PFUDB.
Description: PI-PFU (PF-703) paper leading edge separation fan /Rr1 (FM4) rotation abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Paper leading edge separation fan /Rr1 (FM4: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 6-F) 3. Replace FM4 4. Replace PFUDB.
Description: PI-PFU (PF-703) paper leading edge separation fan /Rr2 (FM8) power abnormality. The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • Paper leading edge separation fan /Rr2 (FM8: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 11-F) 3. Replace FM8 and PFUDB.
Description: PI-PFU (PF-703) paper leading edge separation fan /Rr2 (FM8) rotation abnormality. The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Paper leading edge separation fan /Rr2 (FM8: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 11-F) 3. Replace FM8. 4. Replace PFUDB.
Description: PI-PFU (PF-703) paper leading edge separation fan /Rr3 (FM12) power abnormality. The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • Paper leading edge separation fan /Rr3 (FM12: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 19-F) 3. Replace FM12 and PFUDB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.